Cali-GrafCali-Graf
MicroinverterNorthern Electric & Power

Northern Electric & Power BDHX-2000T-208

Microinverter. 1 model, 2.08 kW AC at 208 V.

UL 1741 SBCEC listed · Jul 21, 2026
  • Rated AC power2.08 kW
  • CEC weighted efficiency95.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026)

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026)
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

CEC Grid Support Inverter List (Oct 7, 2026) · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
BDHX-2000T-208: max DC 55 V · MPPT 22–55 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range0.2—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range0.2—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✓ Within range0.19—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✓ Within range0.19—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✓ Within range0.21—
Silfab Solar SIL-440QD440 W41.1 / 28 V✓ Within range0.21—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✓ Within range0.21—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✓ Within range0.21—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.22—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✓ Within range0.2—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✓ Within range0.21—
Tesla TSP-420420 W43.4 / 27.7 V✓ Within range0.2—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 2.08 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Northern Electric & Power BDHX-xxxxT-2082.08 kW–2.08 kW95.5%22–55 VYes20260
APsystems (Altenergy Power System) QSxxxx1.2 kW–1.92 kW96.5%27–48 V2 of 32025—
Sol-Ark SA-MP-1000-208/240V1 kW–1,000 kW96.0%40–55 VYes2025—
Northern Electric & Power BDM-xxx-208A300 W–2 kW96.5%22–55 VYes2024—
Hoymiles HMT-xxxx-4T-208-NA1.44 kW–1.92 kW96.5%28–48 VYes2024—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Northern Electric & Power

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

BDM-xxx-277ABDM-xxxx-LVBDM-xxx-208ABDM-xxx-240ABDM

Questions & answers

How efficient is the Northern Electric & Power BDHX-xxxxT-208?

The California Energy Commission lists a weighted efficiency of 95.5% for Northern Electric & Power BDHX-xxxxT-208 models, measured at six power levels and three DC voltages.

Is the Northern Electric & Power BDHX-xxxxT-208 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the BDHX-2000T-208’s DC input voltage range?

CEC tested it at 22–55 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  3. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  4. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).