Microinverter. 5 models, 319 W–475 W AC at 208 V / 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| MIS-350-1NA | 319 W | 240 V | 330 W | 330 W | 97.0% | 27–48 V | Mar 11, 2025 | SB |
| MIS-400-1NA | 360 W | 240 V | 368 W | 368 W | 97.0% | 28–48 V | Mar 11, 2025 | SB |
| MIS-450-1NA | 410 W | 240 V | 421 W | 421 W | 97.0% | 30–48 V | Mar 11, 2025 | SB |
| MIS-500-1NA | 475 W | 208 V | 480 W | 480 W | 96.5% | 32–48 V | Mar 11, 2025 | SB |
| MIS-500-1NA | 475 W | 240 V | 476 W | 476 W | 96.5% | 32–48 V | Mar 11, 2025 | SB |
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ✗ Cold Voc above max input | 0.97 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ✗ Cold Voc above max input | 0.97 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.95 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ⚠ Below MPPT at peak heat | 0.96 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ⚠ Below MPPT at peak heat | 1.05 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ⚠ Below MPPT at peak heat | 1.05 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.02 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.02 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 1.09 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.97 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.02 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ⚠ Below MPPT at peak heat | 1 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Hoymiles MIS-xxx-1NA | 319 W–475 W | 97.0% | 30–48 V | Yes | 2025 | 0 |
| Enphase Energy IQ8 Series | 240 W–633 W | 97.5% | 25–95 V | 44 of 45 | 2025 | 1,104 |
| Enphase Energy IQ7 Series | 190 W–384 W | 97.5% | 22–64 V | 114 of 119 | 2022 | 471 |
| Hoymiles HM-xxxNT | 295 W–1.44 kW | 96.5% | 29–48 V | 11 of 12 | 2023 | 3 |
| Enphase Energy IQ9 Series | 405 W–440 W | 97.5% | 28–45 V | Yes | 2026 | — |
The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Hoymiles MIS-xxx-1NA models, measured at six power levels and three DC voltages.
The CEC list includes 5 models from 319 W to 475 W AC: MIS-350-1NA, MIS-400-1NA, MIS-450-1NA, MIS-500-1NA, MIS-500-1NA.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
CEC tested it at 30–48 V DC.