MicroinverterHoymiles

Hoymiles HMT-1800-4T-208-NA

Microinverter. 3 models, 1.44 kW–1.92 kW AC at 208 V.

UL 1741 SBCEC listed · Feb 1, 2024Rapid shutdown
Model
  • Rated AC power1.73 kW
  • CEC weighted efficiency96.5%
  • Max DC input65 V

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 3 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
HMT-1600-4T-208-NA1.44 kW208 V1.44 kW1.44 kW96.5%28–48 VFeb 1, 2024SB
HMT-1800-4T-208-NA1.73 kW208 V1.73 kW1.73 kW96.5%31–48 VFeb 1, 2024SB
HMT-2000-4T-208-NA1.92 kW208 V1.92 kW1.92 kW96.5%32–48 VFeb 1, 2024SB

DC input (PV side)

Hoymiles datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

Hoymiles datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Hoymiles datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Hoymiles datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Hoymiles datasheet

Monitoring & communication

Hoymiles datasheet

Size, weight & environment

Hoymiles datasheet

Panel compatibility & string sizing

Hoymiles datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HMT-1800-4T-208-NA: max DC 65 V · MPPT 16–60 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range0.24—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range0.24—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✓ Within range0.23—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✓ Within range0.23—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✓ Within range0.25—
Silfab Solar SIL-440QD440 W41.1 / 28 V✓ Within range0.25—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✓ Within range0.25—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✓ Within range0.25—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.27—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✓ Within range0.24—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✓ Within range0.25—
Tesla TSP-420420 W43.4 / 27.7 V✓ Within range0.24—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 1.73 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Hoymiles HMT-xxxx-4T-208-NA1.44 kW–1.92 kW96.5%31–48 VYes20240
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Northern Electric & Power BDHX-xxxxT-2082.08 kW–2.08 kW95.5%22–55 VYes2026—
APsystems (Altenergy Power System) QSxxxx1.2 kW–1.92 kW96.5%27–48 V2 of 32025—
Sol-Ark SA-MP-1000-208/240V1 kW–1,000 kW96.0%40–55 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Hoymiles

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

HM-xxxNT · 3 permitsHMS-xxx-1WM-LVMIS-xxx-1A-NAMIS-xxx-1NAMIS-xxx-2NAHM-xxxNHMS-xxx-1A-NAHMS-xxx-1T-NAHMS-xxx-2T-NAHMS-xxxx-4T-NAHMS-xxx-1D-NAHMS-xxx-2D-NA

Questions & answers

How efficient is the Hoymiles HMT-xxxx-4T-208-NA?

The California Energy Commission lists a weighted efficiency of 96.5% for Hoymiles HMT-xxxx-4T-208-NA models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 96.5%.

What sizes does the Hoymiles HMT-xxxx-4T-208-NA come in?

The CEC list includes 3 models from 1.44 kW to 1.92 kW AC: HMT-1600-4T-208-NA, HMT-1800-4T-208-NA, HMT-2000-4T-208-NA.

Is the Hoymiles HMT-xxxx-4T-208-NA certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the HMT-1800-4T-208-NA’s DC input voltage range?

Max DC input voltage is 65 V per the datasheet. MPPT operating range 16–60 V. CEC tested it at 31–48 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Hoymiles — manufacturer datasheet “PRODUCT BROCHURE 2023 FOR NORTH AMERICA”.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).