Hoymiles HMS-1500-4T-NA

Microinverter. 7 models, 1 kW–1.92 kW AC at 208 V / 240 V.

UL 1741 SB · 4 of 7 modelsCEC listed · Mar 1, 2021Rapid shutdown
Model
  • Rated AC power1.5 kW
  • CEC weighted efficiency96.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 7 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
HMS-1000-4T-NA1 kW240 V985 W985 W96.5%32–48 VMar 1, 2021—
HMS-1200-4T-NA1.2 kW240 V1.21 kW1.21 kW96.5%32–48 VMar 1, 2021—
HMS-1600-4T-NA1.44 kW240 V1.45 kW1.45 kW96.5%29–48 VFeb 21, 2023SB
HMS-1500-4T-NA1.5 kW240 V1.44 kW1.44 kW96.5%36–48 VMar 1, 2021—
HMS-1800-4T-NA1.66 kW240 V1.67 kW1.67 kW96.5%32–48 VFeb 21, 2023SB
HMS-2000-4T-NA1.92 kW208 V1.93 kW1.93 kW96.5%34–48 VFeb 21, 2023SB
HMS-2000-4T-NA1.92 kW240 V1.93 kW1.93 kW96.5%34–48 VFeb 21, 2023SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Hoymiles datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Hoymiles datasheets

Monitoring & communication

Hoymiles datasheet

Size, weight & environment

Hoymiles datasheet

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HMS-1500-4T-NA: max DC 48 V · MPPT 36–48 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.28—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.28—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.28—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat0.28—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V⚠ Below MPPT at peak heat0.31—
Silfab Solar SIL-440QD440 W41.1 / 28 V⚠ Below MPPT at peak heat0.31—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.3—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.3—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.32—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.28—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.3—
Tesla TSP-420420 W43.4 / 27.7 V⚠ Below MPPT at peak heat0.29—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 1.5 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Hoymiles HMS-xxxx-4T-NA1 kW–1.92 kW96.5%36–48 V—20230
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
FOXESS M1-xxxx-NA600 W–1.2 kW95.5%35–50 VYes2026—
APsystems (Altenergy Power System) QSxxxx1.2 kW–1.92 kW96.5%27–48 V2 of 32025—
Sol-Ark SA-MP-1000-208/240V1 kW–1,000 kW96.0%40–55 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Approved in other markets

Clean Energy Council (Australia)
ModelApprovedExpiresStandards
HMS-1600-4TSep 2, 2024Sep 2, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
HMS-1800-4TSep 2, 2024Sep 2, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
HMS-2000-4TSep 2, 2024Sep 2, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020

About Hoymiles

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

HM-xxxNT · 3 permitsHMS-xxx-1WM-LVMIS-xxx-1A-NAMIS-xxx-1NAMIS-xxx-2NAHMT-xxxx-4T-208-NAHM-xxxNHMS-xxx-1A-NAHMS-xxx-1T-NAHMS-xxx-2T-NAHMS-xxx-1D-NAHMS-xxx-2D-NA

Questions & answers

How efficient is the Hoymiles HMS-xxxx-4T-NA?

The California Energy Commission lists a weighted efficiency of 96.5% for Hoymiles HMS-xxxx-4T-NA models, measured at six power levels and three DC voltages.

What sizes does the Hoymiles HMS-xxxx-4T-NA come in?

The CEC list includes 7 models from 1 kW to 1.92 kW AC: HMS-1000-4T-NA, HMS-1200-4T-NA, HMS-1600-4T-NA, HMS-1500-4T-NA, HMS-1800-4T-NA, HMS-2000-4T-NA, HMS-2000-4T-NA.

Is the Hoymiles HMS-xxxx-4T-NA certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 4 of 7 models.

What is the HMS-1500-4T-NA’s DC input voltage range?

CEC tested it at 36–48 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Hoymiles — manufacturer datasheet “Open Energy For All Microinverter Description Datasheet Hoymiles new microinverter HMS-2000 series are suitable for”.
  3. Hoymiles — manufacturer datasheet “PRODUCT BROCHURE 2023 FOR NORTH AMERICA”.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  7. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).