Microinverter. 7 models, 1 kW–1.92 kW AC at 208 V / 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| HMS-1000-4T-NA | 1 kW | 240 V | 985 W | 985 W | 96.5% | 32–48 V | Mar 1, 2021 | — |
| HMS-1200-4T-NA | 1.2 kW | 240 V | 1.21 kW | 1.21 kW | 96.5% | 32–48 V | Mar 1, 2021 | — |
| HMS-1600-4T-NA | 1.44 kW | 240 V | 1.45 kW | 1.45 kW | 96.5% | 29–48 V | Feb 21, 2023 | SB |
| HMS-1500-4T-NA | 1.5 kW | 240 V | 1.44 kW | 1.44 kW | 96.5% | 36–48 V | Mar 1, 2021 | — |
| HMS-1800-4T-NA | 1.66 kW | 240 V | 1.67 kW | 1.67 kW | 96.5% | 32–48 V | Feb 21, 2023 | SB |
| HMS-2000-4T-NA | 1.92 kW | 208 V | 1.93 kW | 1.93 kW | 96.5% | 34–48 V | Feb 21, 2023 | SB |
| HMS-2000-4T-NA | 1.92 kW | 240 V | 1.93 kW | 1.93 kW | 96.5% | 34–48 V | Feb 21, 2023 | SB |
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ✗ Cold Voc above max input | 0.28 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ✗ Cold Voc above max input | 0.28 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.28 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ⚠ Below MPPT at peak heat | 0.28 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ⚠ Below MPPT at peak heat | 0.31 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ⚠ Below MPPT at peak heat | 0.31 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.3 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.3 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 0.32 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.28 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.3 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ⚠ Below MPPT at peak heat | 0.29 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Hoymiles HMS-xxxx-4T-NA | 1 kW–1.92 kW | 96.5% | 36–48 V | — | 2023 | 0 |
| Hoymiles HM-xxxNT | 295 W–1.44 kW | 96.5% | 29–48 V | 11 of 12 | 2023 | 3 |
| FOXESS M1-xxxx-NA | 600 W–1.2 kW | 95.5% | 35–50 V | Yes | 2026 | — |
| APsystems (Altenergy Power System) QSxxxx | 1.2 kW–1.92 kW | 96.5% | 27–48 V | 2 of 3 | 2025 | — |
| Sol-Ark SA-MP-1000-208/240V | 1 kW–1,000 kW | 96.0% | 40–55 V | Yes | 2025 | — |
| Model | Approved | Expires | Standards |
|---|---|---|---|
| HMS-1600-4T | Sep 2, 2024 | Sep 2, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| HMS-1800-4T | Sep 2, 2024 | Sep 2, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| HMS-2000-4T | Sep 2, 2024 | Sep 2, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
The California Energy Commission lists a weighted efficiency of 96.5% for Hoymiles HMS-xxxx-4T-NA models, measured at six power levels and three DC voltages.
The CEC list includes 7 models from 1 kW to 1.92 kW AC: HMS-1000-4T-NA, HMS-1200-4T-NA, HMS-1600-4T-NA, HMS-1500-4T-NA, HMS-1800-4T-NA, HMS-2000-4T-NA, HMS-2000-4T-NA.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 4 of 7 models.
CEC tested it at 36–48 V DC.