Cali-GrafCali-Graf
MicroinverterHoymiles

Hoymiles HMS-400-1T-NA

Microinverter. 5 models, 295 W–475 W AC at 240 V.

UL 1741 SB · 4 of 5 modelsCEC listed · Mar 11, 2021Rapid shutdown
Model
  • Rated AC power360 W
  • CEC weighted efficiency96.5%
  • Max DC input65 V

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 5 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
HMS-300-1T-NA295 W240 V295 W295 W96.5%29–48 VMar 11, 2021—
HMS-350-1T-NA349 W240 V322 W322 W96.5%33–48 VMar 11, 2021SB
HMS-400-1T-NA382 W240 V362 W362 W96.5%34–48 VMar 11, 2021SB
HMS-450-1T-NA410 W240 V411 W411 W96.5%36–48 VApr 11, 2023SB
HMS-500-1T-NA475 W240 V476 W476 W96.5%38–48 VApr 11, 2023SB

DC input (PV side)

Hoymiles datasheets · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

Hoymiles datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Hoymiles datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Hoymiles datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Hoymiles datasheets

Monitoring & communication

Hoymiles datasheet

Size, weight & environment

Hoymiles datasheet

Panel compatibility & string sizing

Hoymiles datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HMS-400-1T-NA: max DC 65 V · MPPT 16–60 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range1.13—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range1.13—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✓ Within range1.11—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✓ Within range1.12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✓ Within range1.22—
Silfab Solar SIL-440QD440 W41.1 / 28 V✓ Within range1.22—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✓ Within range1.19—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✓ Within range1.19—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input1.27—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✓ Within range1.13—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✓ Within range1.19—
Tesla TSP-420420 W43.4 / 27.7 V✓ Within range1.16—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 360 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Hoymiles HMS-xxx-1T-NA295 W–475 W96.5%34–48 VYes20230
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Enphase Energy IQ7 Series190 W–384 W97.5%22–64 V114 of 1192022471
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Enphase Energy IQ9 Series405 W–440 W97.5%28–45 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Hoymiles

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

HM-xxxNT · 3 permitsHMS-xxx-1WM-LVMIS-xxx-1A-NAMIS-xxx-1NAMIS-xxx-2NAHMT-xxxx-4T-208-NAHM-xxxNHMS-xxx-1A-NAHMS-xxx-2T-NAHMS-xxxx-4T-NAHMS-xxx-1D-NAHMS-xxx-2D-NA

Questions & answers

How efficient is the Hoymiles HMS-xxx-1T-NA?

The California Energy Commission lists a weighted efficiency of 96.5% for Hoymiles HMS-xxx-1T-NA models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 96.7%.

What sizes does the Hoymiles HMS-xxx-1T-NA come in?

The CEC list includes 5 models from 295 W to 475 W AC: HMS-300-1T-NA, HMS-350-1T-NA, HMS-400-1T-NA, HMS-450-1T-NA, HMS-500-1T-NA.

Is the Hoymiles HMS-xxx-1T-NA certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 4 of 5 models.

What is the HMS-400-1T-NA’s DC input voltage range?

Max DC input voltage is 65 V per the datasheet. MPPT operating range 16–60 V. CEC tested it at 34–48 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Hoymiles — manufacturer datasheet “Open Energy For All Microinverter Description Datasheet Hoymiles new microinverter HMS-500 series are suitable for”.
  3. Hoymiles — manufacturer datasheet “PRODUCT BROCHURE 2023 FOR NORTH AMERICA”.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  6. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).