Microinverter. 4 models, 300 W–305 W AC at 208 V / 240 V.
UL 1741 SBCEC listed · Mar 11, 2020
Model
Rated AC power305 W
CEC weighted efficiency97.0%
Models & power ratings
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
Model
Nominal AC
Grid voltage
CEC continuous
Rated AC (SAM)
CEC weighted eff.
DC test window
CEC listed
UL 1741 SB
XACM-IQ7-LR6-60PB-300M
300 W
208 V
240 W
240 W
97.0%
27–37 V
Mar 11, 2020
SB
XACM-IQ7-LR6-60PB-300M
300 W
240 V
240 W
240 W
97.0%
27–37 V
Mar 11, 2020
SB
XACM-IQ7-LR6-60PB-305M
305 W
208 V
240 W
240 W
97.0%
27–37 V
Mar 11, 2020
SB
XACM-IQ7-LR6-60PB-305M
305 W
240 V
240 W
240 W
97.0%
27–37 V
Mar 11, 2020
SB
4 more listings are microinverters sold only inside AC modules — not shown here.
DC input (PV side)
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC test DC voltages (min / nom / max)27 / 32 / 37 V
DC input at rated output (CEC test)247 W
Efficiency
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency97.0%
Night-time standby (tare)0.03 W
Power to start converting1.8 W
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.
Grid & smart-inverter certification
CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB (3rd ed.)Yes — UL, certificate Jun 8, 2022
UL 1741 SA (SA8–SA13)Yes — UL
Firmware tested (SA)V04.27.04, V04.28.07, V04.30.22 and 3 more
Volt-VAr with reactive power priority (SA13)Yes
Freq-Watt / Volt-Watt (SA14–15)Yes
Disable permit service / limit active power (SA17–18)Yes
CSIP (IEEE 2030.5) conformanceVia gateway during testing (Y*)
Monitor key data & scheduling (Rule 21 Phase 3)Yes (attested May 11, 2020)
CEC listedMar 11, 2020
Last CEC updateOct 3, 2022
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.
Compare with similar 305 W inverters
CEC Grid Support Inverter List (Oct 7, 2026) · building permits
Inverter
Power
CEC weighted eff.
DC test window
UL 1741 SB
Latest CEC
SoCal permits
Enphase Energy XACM-IQ7-LR6-60PB-xxxM
300 W–305 W
97.0%
27–37 V
Yes
2020
0
Enphase Energy IQ8 Series
240 W–633 W
97.5%
25–95 V
44 of 45
2025
1,104
Enphase Energy IQ7 Series
190 W–384 W
97.5%
22–64 V
114 of 119
2022
471
Hoymiles HM-xxxNT
295 W–1.44 kW
96.5%
29–48 V
11 of 12
2023
3
Enphase Energy IQ9 Series
405 W–440 W
97.5%
28–45 V
Yes
2026
—
Same type and grid voltage, power range covering this model; same fields from the same sources.
About Enphase Energy
CEC Grid Support Inverter List (Oct 7, 2026)
ManufacturerEnphase Energy
Listed in CEC asEnphase Energy, Inc.
Websiteenphase.com
Models on CEC lists223
Other series
IQ8 Series · 1104 permitsIQ7 Series · 471 permitsIQ8-3P Series · 1 permitsIQ9 SeriesIQ9-3P Series
Questions & answers
How efficient is the Enphase Energy XACM-IQ7-LR6-60PB-xxxM?
The California Energy Commission lists a weighted efficiency of 97.0% for Enphase Energy XACM-IQ7-LR6-60PB-xxxM models, measured at six power levels and three DC voltages.
What sizes does the Enphase Energy XACM-IQ7-LR6-60PB-xxxM come in?
The CEC list includes 4 models from 300 W to 305 W AC: XACM-IQ7-LR6-60PB-300M, XACM-IQ7-LR6-60PB-300M, XACM-IQ7-LR6-60PB-305M, XACM-IQ7-LR6-60PB-305M.
Is the Enphase Energy XACM-IQ7-LR6-60PB-xxxM certified to UL 1741 SB?
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
What is the XACM-IQ7-LR6-60PB-305M’s DC input voltage range?
CEC tested it at 27–37 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.