Cali-GrafCali-Graf
MicroinverterEnphase Energy

Enphase Energy IQ8PLUS-72-2-US

Microinverter. 12 models, 240 W–633 W AC at 208 V / 240 V.

UL 1741 SB · 44 of 45 modelsCEC listed · May 3, 2021Rapid shutdownInstalled in 1,104 SoCal permits
Model
  • Rated AC power290 W
  • CEC weighted efficiency97.0%
  • Max DC input60 V

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · building permits · 12 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SBIn permits
IQ8-60-2-US +1 SKU240 W240 V240 W240 W97.0%27–37 VMay 3, 2021SB12
IQ8PLUS-72-2-US +3 SKU295 W240 V295 W290 W97.0%27–45 VMay 3, 2021SB349
IQ8MC-72-M-US +3 SKU310 W208 V310 W310 W96.5%25–45 VJul 21, 2023SB36
IQ8MC-72-M-US +3 SKU320 W240 V320 W320 W97.0%25–45 VJul 21, 2023SB36
IQ8M-72-2-US +1 SKU325 W240 V325 W325 W97.0%30–45 VMay 3, 2021SB155
IQ8AC-72-M-US +3 SKU345 W208 V345 W345 W96.5%28–45 VJul 21, 2023SB3
IQ8A-72-2-US +5 SKU349 W240 V349 W349 W97.0%32–45 VMay 3, 2021SB50
IQ8HC-72-M-DOM-US +7 SKU360 W208 V360 W360 W96.5%30–45 VFeb 21, 2025SB132
IQ8H-240-72-2-US +1 SKU380 W240 V380 W380 W97.0%36–45 VMay 3, 2021SB15
IQ8HC-72-M-DOM-US +5 SKU384 W240 V384 W380 W97.0%30–45 VOct 1, 2024SB132
IQ8P-72-2-US +1 SKU475 W240 V475 W475 W97.5%36–55 VFeb 1, 2024SB—
IQ8D-72-E-US633 W208 V640 W640 W97.5%60–95 VJan 3, 2022——

DC input (PV side)

Enphase Energy datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

AC output (grid side)

Enphase Energy datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Enphase Energy datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Enphase Energy datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Enphase Energy datasheet

Monitoring & communication

Enphase Energy datasheet

Size, weight & environment

Enphase Energy datasheet

Panel compatibility & string sizing

Enphase Energy datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
IQ8PLUS-72-2-US: max DC 60 V · MPPT 29–45 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range1.41201
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat1.4829
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V⚠ Below MPPT at peak heat1.5220
Silfab Solar SIL-440QD440 W41.1 / 28 V⚠ Below MPPT at peak heat1.5214
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat1.4111
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat1.46
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range1.41—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat1.38—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat1.48—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat1.48—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input1.59—
Tesla TSP-420420 W43.4 / 27.7 V⚠ Below MPPT at peak heat1.45—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Battery & storage pairings

building permits

Batteries installed with it in SoCal

Enphase IQ Battery 5P
211
Enphase IQ Battery 10C
80
Tesla Powerwall 2
27
Enphase IQ Battery
22
Tesla Powerwall 3
22
FranklinWH aPower 2
15
Enphase IQ Battery 10
13
Enphase IQ Battery 10T
12

What it's installed with

building permits

Panels

Qcells Q.PEAK DUO
201
Qcells (model not specified)
72
REC Alpha Pure
52
REC (model not specified)
39
Qcells Q.TRON
29

Batteries

Enphase IQ Battery 5P
211
Enphase IQ Battery 10C
80
Tesla Powerwall 2
27
Enphase IQ Battery
22
Tesla Powerwall 3
22

Gateways & interfaces

Enphase IQ Combiner
210
Enphase IQ Gateway
39
Tesla Backup Gateway
35
Enphase IQ System Controller
34
Enphase IQ Meter Collar
20
Permits naming both; 942 of 1104 permits list other equipment.

Installed in Southern California

building permits
1,104
Permits name it
Feb 2022 – Sep 2026
6
Jurisdictions so far
LA County (unincorp.) (892), Palmdale (128), Huntington Beach (47), Ch
17,088
Units listed
median 17 per permit
7 kW
Typical system
median of 759 permits

Permits over time

2Q1 ’222967Q3 ’228491Q1 ’2311457Q3 ’235153Q1 ’247536Q3 ’245343Q1 ’254265Q3 ’257739Q1 ’266066Q3 ’26permits per quarter

Model named in permit

IQ8PLUS-72-2-US
295
IQ8M-72-2-US
145
IQ8HC-72-M-DOM-US
99
IQ8PLUS-72-M-US
54
IQ8A-72-2-US
47
IQ8MC-72-M-US
35

Top ZIP codes

  • ZIP 9100191
  • ZIP 9355064
  • ZIP 9174546
  • ZIP 9060438
  • ZIP 9355138
  • ZIP 9355234
  • ZIP 9029030
  • ZIP 9121427
  • Other ZIP codes23
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Who installs IQ8 Series in SoCal

building permits · CSLB License Master
and 33 more licensed installers

Compare with similar 290 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Enphase Energy IQ8 Series240 W–633 W97.0%27–45 VYes2025920
Enphase Energy IQ7 Series190 W–384 W97.5%22–64 V114 of 1192022471
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Qcells Q.MI.380C-G2330 W–380 W97.0%30–41 VYes2026—
Qcells Q.MI.xxxB-P2384 W–384 W97.0%30–40 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Approved in other markets

Clean Energy Council (Australia)
ModelApprovedExpiresStandards
IQ8AC-72-M-ACM-INTMar 19, 2024Mar 19, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
IQ8AC-72-M-INTJul 13, 2023Jan 9, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
IQ8HC-72-M-ACM-INTMar 19, 2024Mar 19, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
IQ8HC-72-M-INTJul 13, 2023Jan 9, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
IQ8MC-72-M-ACM-INTJul 25, 2023Jan 21, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020

About Enphase Energy

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

IQ7 Series · 471 permitsIQ8-3P Series · 1 permitsIQ9 SeriesIQ9-3P Series

Documents

manufacturer documents

Questions & answers

How efficient is the Enphase Energy IQ8 Series?

The California Energy Commission lists a weighted efficiency of 96.5–97.5% for Enphase Energy IQ8 Series models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 97.6%.

What sizes does the Enphase Energy IQ8 Series come in?

The CEC list includes 12 models from 240 W to 633 W AC: IQ8-60-2-US, IQ8PLUS-72-2-US, IQ8MC-72-M-US, IQ8MC-72-M-US, IQ8M-72-2-US, IQ8AC-72-M-US, IQ8A-72-2-US, IQ8HC-72-M-DOM-US….

Is the Enphase Energy IQ8 Series certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 44 of 45 models.

Can the Enphase Energy IQ8 Series be used with a battery?

In Southern California permits it was installed with Enphase IQ Battery 5P, Enphase IQ Battery 10C, Tesla Powerwall 2.

What is the IQ8PLUS-72-2-US’s DC input voltage range?

Max DC input voltage is 60 V per the datasheet. MPPT operating range 29–45 V. CEC tested it at 27–45 V DC.

Who installs it in Southern California?

Building permits name this series 1104 times (Feb 2022 – Sep 2026). The most active licensed installers are Better Earth Electric Inc, South West Builders, Lgcy Electric.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Enphase Energy — manufacturer datasheet “Easy to install IQ8M and IQ8A Microinverters • Lightweight and compact with plug-”.
  3. Enphase Energy — manufacturer datasheet “IQ8 and IQ8+ Microinverters Easy to install energy systems.”.
  4. Enphase Energy — document library on the manufacturer’s website (links above).
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  8. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Feb 2022 – Aug 2026); City of Palmdale (Nov 2023 – Sep 2026); City of Huntington Beach (Feb 2024 – May 2026); City of Chula Vista (Mar 2026 – Sep 2026); LADBS, City of Los Angeles (Aug 2022 – Mar 2023); San Diego County (Feb 2025 – Apr 2025). Equipment matched from permit descriptions by model number.
  10. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).