Microinverter. 12 models, 240 W–633 W AC at 208 V / 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB | In permits |
|---|---|---|---|---|---|---|---|---|---|
| IQ8-60-2-US +1 SKU | 240 W | 240 V | 240 W | 240 W | 97.0% | 27–37 V | May 3, 2021 | SB | 12 |
| IQ8PLUS-72-2-US +3 SKU | 295 W | 240 V | 295 W | 290 W | 97.0% | 27–45 V | May 3, 2021 | SB | 349 |
| IQ8MC-72-M-US +3 SKU | 310 W | 208 V | 310 W | 310 W | 96.5% | 25–45 V | Jul 21, 2023 | SB | 36 |
| IQ8MC-72-M-US +3 SKU | 320 W | 240 V | 320 W | 320 W | 97.0% | 25–45 V | Jul 21, 2023 | SB | 36 |
| IQ8M-72-2-US +1 SKU | 325 W | 240 V | 325 W | 325 W | 97.0% | 30–45 V | May 3, 2021 | SB | 155 |
| IQ8AC-72-M-US +3 SKU | 345 W | 208 V | 345 W | 345 W | 96.5% | 28–45 V | Jul 21, 2023 | SB | 3 |
| IQ8A-72-2-US +5 SKU | 349 W | 240 V | 349 W | 349 W | 97.0% | 32–45 V | May 3, 2021 | SB | 50 |
| IQ8HC-72-M-DOM-US +7 SKU | 360 W | 208 V | 360 W | 360 W | 96.5% | 30–45 V | Feb 21, 2025 | SB | 132 |
| IQ8H-240-72-2-US +1 SKU | 380 W | 240 V | 380 W | 380 W | 97.0% | 36–45 V | May 3, 2021 | SB | 15 |
| IQ8HC-72-M-DOM-US +5 SKU | 384 W | 240 V | 384 W | 380 W | 97.0% | 30–45 V | Oct 1, 2024 | SB | 132 |
| IQ8P-72-2-US +1 SKU | 475 W | 240 V | 475 W | 475 W | 97.5% | 36–55 V | Feb 1, 2024 | SB | — |
| IQ8D-72-E-US | 633 W | 208 V | 640 W | 640 W | 97.5% | 60–95 V | Jan 3, 2022 | — | — |
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 1.41 | 201 |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.48 | 29 |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ⚠ Below MPPT at peak heat | 1.52 | 20 |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ⚠ Below MPPT at peak heat | 1.52 | 14 |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 1.41 | 11 |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ⚠ Below MPPT at peak heat | 1.4 | 6 |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 1.41 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 1.38 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.48 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 1.48 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 1.59 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ⚠ Below MPPT at peak heat | 1.45 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Enphase Energy IQ8 Series | 240 W–633 W | 97.0% | 27–45 V | Yes | 2025 | 920 |
| Enphase Energy IQ7 Series | 190 W–384 W | 97.5% | 22–64 V | 114 of 119 | 2022 | 471 |
| Hoymiles HM-xxxNT | 295 W–1.44 kW | 96.5% | 29–48 V | 11 of 12 | 2023 | 3 |
| Qcells Q.MI.380C-G2 | 330 W–380 W | 97.0% | 30–41 V | Yes | 2026 | — |
| Qcells Q.MI.xxxB-P2 | 384 W–384 W | 97.0% | 30–40 V | Yes | 2026 | — |
| Model | Approved | Expires | Standards |
|---|---|---|---|
| IQ8AC-72-M-ACM-INT | Mar 19, 2024 | Mar 19, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| IQ8AC-72-M-INT | Jul 13, 2023 | Jan 9, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| IQ8HC-72-M-ACM-INT | Mar 19, 2024 | Mar 19, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| IQ8HC-72-M-INT | Jul 13, 2023 | Jan 9, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| IQ8MC-72-M-ACM-INT | Jul 25, 2023 | Jan 21, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
The California Energy Commission lists a weighted efficiency of 96.5–97.5% for Enphase Energy IQ8 Series models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 97.6%.
The CEC list includes 12 models from 240 W to 633 W AC: IQ8-60-2-US, IQ8PLUS-72-2-US, IQ8MC-72-M-US, IQ8MC-72-M-US, IQ8M-72-2-US, IQ8AC-72-M-US, IQ8A-72-2-US, IQ8HC-72-M-DOM-US….
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 44 of 45 models.
In Southern California permits it was installed with Enphase IQ Battery 5P, Enphase IQ Battery 10C, Tesla Powerwall 2.
Max DC input voltage is 60 V per the datasheet. MPPT operating range 29–45 V. CEC tested it at 27–45 V DC.
Building permits name this series 1104 times (Feb 2022 – Sep 2026). The most active licensed installers are Better Earth Electric Inc, South West Builders, Lgcy Electric.