Microinverter. 1 model, 1.8 kW AC at 480 V.
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 0.23 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 0.23 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.22 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ⚠ Below MPPT at peak heat | 0.22 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ⚠ Below MPPT at peak heat | 0.24 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ⚠ Below MPPT at peak heat | 0.24 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.24 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.24 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 0.25 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.23 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.24 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ⚠ Below MPPT at peak heat | 0.23 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| APsystems (Altenergy Power System) QTx-480 | 1.8 kW–1.8 kW | 95.5% | 34–42 V | Yes | 2022 | 0 |
| APsystems (Altenergy Power System) QT2 | 1.73 kW–1.8 kW | 96.0% | 34–42 V | Yes | 2022 | — |
The California Energy Commission lists a weighted efficiency of 95.5% for APsystems (Altenergy Power System) QTx-480 models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 96.5%.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
Max DC input voltage is 60 V per the datasheet. MPPT operating range 30–45 V. CEC tested it at 34–42 V DC.
10 years standard (manufacturer datasheet).