Cali-GrafCali-Graf
String inverterYaskawa Solectria Solar

Yaskawa Solectria Solar XGI 1500 250/250-600

String inverter. 1 model, 250 kW AC at 600 V.

UL 1741 SBCEC listed · Apr 21, 2023
  • Rated AC power250 kW
  • CEC weighted efficiency98.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
XGI 1500 250/250-600: max DC 1,250 V · MPPT 860–1,250 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 250 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Yaskawa Solectria Solar XGI 1500 xxx/xxx-600250 kW–250 kW98.5%860–1,250 VYes20230
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Yaskawa Solectria Solar

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVI xxTL-480PVI-xxTL-208XGI 1500-xxx-480-DCGXGI 1500-xxx-600-DCGXGI 1500-xxx/150-UL-AXGI 1500-xxx/166-UL-AXGI 1500-xxx/xxx-480-DCGXGI 1500-xxx/xxx-600-DCGXGI 1500-xxx/xxx-UL-APVI-xxTL-480-V2XGI 1500 xxx-480XGI 1500 xxx-600

Questions & answers

How efficient is the Yaskawa Solectria Solar XGI 1500 xxx/xxx-600?

The California Energy Commission lists a weighted efficiency of 98.5% for Yaskawa Solectria Solar XGI 1500 xxx/xxx-600 models, measured at six power levels and three DC voltages.

Is the Yaskawa Solectria Solar XGI 1500 xxx/xxx-600 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the XGI 1500 250/250-600’s DC input voltage range?

CEC tested it at 860–1,250 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).