Cali-GrafCali-Graf
String inverterYaskawa Solectria Solar

Yaskawa Solectria Solar PVI25TL-480-R

String inverter. 2 models, 20 kW–25 kW AC at 480 V.

UL 1741 SB · 1 of 2 modelsCEC listed · Feb 21, 2020
Model
  • Rated AC power25 kW
  • CEC weighted efficiency98.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
PVI20TL-480-R20 kW480 V20 kW20 kW98.0%560–850 VFeb 21, 2020—
PVI25TL-480-R25 kW480 V25 kW25 kW98.0%560–850 VFeb 21, 2020SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
PVI25TL-480-R: max DC 850 V · MPPT 560–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 25 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Yaskawa Solectria Solar PVIxxTL-480-R20 kW–25 kW98.0%560–850 VYes20200
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO-R/US-48020 kW–25 kW98.0%560–850 VYes20201
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
SMA STP xx-US-5013 kW–30 kW98.0%230–800 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Yaskawa Solectria Solar

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVI xxTL-480PVI-xxTL-208XGI 1500-xxx-480-DCGXGI 1500-xxx-600-DCGXGI 1500-xxx/150-UL-AXGI 1500-xxx/166-UL-AXGI 1500-xxx/xxx-480-DCGXGI 1500-xxx/xxx-600-DCGXGI 1500-xxx/xxx-UL-APVI-xxTL-480-V2XGI 1500 xxx-480XGI 1500 xxx-600

Questions & answers

How efficient is the Yaskawa Solectria Solar PVIxxTL-480-R?

The California Energy Commission lists a weighted efficiency of 98.0% for Yaskawa Solectria Solar PVIxxTL-480-R models, measured at six power levels and three DC voltages.

What sizes does the Yaskawa Solectria Solar PVIxxTL-480-R come in?

The CEC list includes 2 models from 20 kW to 25 kW AC: PVI20TL-480-R, PVI25TL-480-R.

Is the Yaskawa Solectria Solar PVIxxTL-480-R certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 1 of 2 models.

What is the PVI25TL-480-R’s DC input voltage range?

CEC tested it at 560–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).