Cali-GrafCali-Graf
String inverterYaskawa Solectria Solar

Yaskawa Solectria Solar PVI 60TL-480

String inverter. 4 models, 36 kW–100 kW AC at 480 V.

UL 1741 SB · 3 of 4 modelsCEC listed · Oct 1, 2017
Model
  • Rated AC power60 kW
  • CEC weighted efficiency98.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
PVI 36TL-48036 kW480 V36 kW36 kW98.0%540–800 VOct 1, 2017—
PVI 50TL-48050 kW480 V50 kW50 kW98.5%480–850 VOct 1, 2017SB
PVI 60TL-48060 kW480 V60 kW60 kW98.5%540–850 VOct 1, 2017SB
PVI-100TL-480100 kW480 V100 kW100 kW98.0%340–850 VDec 22, 2025SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
PVI 60TL-480: max DC 850 V · MPPT 540–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V20–20—
Silfab Solar SIL-440QD440 W41.1 V28 V20–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V20–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V20–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V20–20—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 60 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Yaskawa Solectria Solar PVI xxTL-48036 kW–100 kW98.5%540–850 VYes20250
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Yaskawa Solectria Solar

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVI-xxTL-208XGI 1500-xxx-480-DCGXGI 1500-xxx-600-DCGXGI 1500-xxx/150-UL-AXGI 1500-xxx/166-UL-AXGI 1500-xxx/xxx-480-DCGXGI 1500-xxx/xxx-600-DCGXGI 1500-xxx/xxx-UL-APVI-xxTL-480-V2XGI 1500 xxx-480XGI 1500 xxx-600XGI 1500 xxx/xxx-480

Questions & answers

How efficient is the Yaskawa Solectria Solar PVI xxTL-480?

The California Energy Commission lists a weighted efficiency of 98.0–98.5% for Yaskawa Solectria Solar PVI xxTL-480 models, measured at six power levels and three DC voltages.

What sizes does the Yaskawa Solectria Solar PVI xxTL-480 come in?

The CEC list includes 4 models from 36 kW to 100 kW AC: PVI 36TL-480, PVI 50TL-480, PVI 60TL-480, PVI-100TL-480.

Is the Yaskawa Solectria Solar PVI xxTL-480 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 3 of 4 models.

What is the PVI 60TL-480’s DC input voltage range?

CEC tested it at 540–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).