Cali-GrafCali-Graf
String inverterYaskawa Solectria Solar

Yaskawa Solectria Solar PVI-36TL-480-V2

String inverter. 1 model, 36 kW AC at 480 V.

UL 1741 SBCEC listed · Jun 12, 2023
  • Rated AC power36 kW
  • CEC weighted efficiency97.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
PVI-36TL-480-V2: max DC 850 V · MPPT 400–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V14–17—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V14–17—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V16–21—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V16–21—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V15–20—
Silfab Solar SIL-440QD440 W41.1 V28 V15–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V15–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V15–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V9–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V16–21—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V15–20—
Tesla TSP-420420 W43.4 V27.7 V15–19—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 36 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Yaskawa Solectria Solar PVI-xxTL-480-V236 kW–36 kW97.5%400–850 VYes20230
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Yaskawa Solectria Solar PVI xxTL-48036 kW–100 kW98.5%340–850 V3 of 42025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Yaskawa Solectria Solar

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVI xxTL-480PVI-xxTL-208XGI 1500-xxx-480-DCGXGI 1500-xxx-600-DCGXGI 1500-xxx/150-UL-AXGI 1500-xxx/166-UL-AXGI 1500-xxx/xxx-480-DCGXGI 1500-xxx/xxx-600-DCGXGI 1500-xxx/xxx-UL-AXGI 1500 xxx-480XGI 1500 xxx-600XGI 1500 xxx/xxx-480

Questions & answers

How efficient is the Yaskawa Solectria Solar PVI-xxTL-480-V2?

The California Energy Commission lists a weighted efficiency of 97.5% for Yaskawa Solectria Solar PVI-xxTL-480-V2 models, measured at six power levels and three DC voltages.

Is the Yaskawa Solectria Solar PVI-xxTL-480-V2 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the PVI-36TL-480-V2’s DC input voltage range?

CEC tested it at 400–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).