Yaskawa Solectria Solar PVI-50TL-208

String inverter. 2 models, 25 kW–50 kW AC at 208 V.

UL 1741 SBCEC listed · Oct 21, 2020
Model
  • Rated AC power50 kW
  • CEC weighted efficiency96.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
PVI 25TL-20825 kW208 V25 kW25 kW96.5%480–850 VOct 21, 2020SB
PVI-50TL-20850 kW208 V50 kW50 kW96.5%200–700 VDec 22, 2025SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
PVI-50TL-208: max DC 700 V · MPPT 200–700 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–14—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–14—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–17—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–17—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V8–17—
Silfab Solar SIL-440QD440 W41.1 V28 V8–17—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V8–16—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V8–16—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–10—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–17—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V8–16—
Tesla TSP-420420 W43.4 V27.7 V8–16—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 50 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Yaskawa Solectria Solar PVI-xxTL-20825 kW–50 kW96.5%200–700 VYes20250
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Solis (Ginlong Technologies) S5-GC60K-LV-US60 kW–60 kW98.0%400–650 VYes2025—
CPS (Chint Power Systems) SCAxxK-T-US-20850 kW–50 kW96.5%200–700 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Yaskawa Solectria Solar

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVI xxTL-480XGI 1500-xxx-480-DCGXGI 1500-xxx-600-DCGXGI 1500-xxx/150-UL-AXGI 1500-xxx/166-UL-AXGI 1500-xxx/xxx-480-DCGXGI 1500-xxx/xxx-600-DCGXGI 1500-xxx/xxx-UL-APVI-xxTL-480-V2XGI 1500 xxx-480XGI 1500 xxx-600XGI 1500 xxx/xxx-480

Questions & answers

How efficient is the Yaskawa Solectria Solar PVI-xxTL-208?

The California Energy Commission lists a weighted efficiency of 96.5% for Yaskawa Solectria Solar PVI-xxTL-208 models, measured at six power levels and three DC voltages.

What sizes does the Yaskawa Solectria Solar PVI-xxTL-208 come in?

The CEC list includes 2 models from 25 kW to 50 kW AC: PVI 25TL-208, PVI-50TL-208.

Is the Yaskawa Solectria Solar PVI-xxTL-208 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the PVI-50TL-208’s DC input voltage range?

CEC tested it at 200–700 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).