Cali-GrafCali-Graf
Hybrid inverterVOLTRONIC POWER TECHNOLOGY (SH…

VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW

Hybrid inverter, dc-coupled hybrid (pv + battery). 2 models, 10 kW AC at 120 V / 240 V.

UL 1741 SBCEC listed · Jun 3, 2024
Model
  • Rated AC power10 kW
  • CEC weighted efficiency95.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
InfiniSolar WP LV 12KW10 kW120 V9.02 kW9.02 kW95.5%285–500 VJun 3, 2024SB
InfiniSolar WP LV 12KW10 kW240 V9.02 kW9.02 kW95.5%285–500 VJun 11, 2024SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
InfiniSolar WP LV 12KW: max DC 500 V · MPPT 285–500 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V10–10—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V10–10—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V12–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V12–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V11–12—
Silfab Solar SIL-440QD440 W41.1 V28 V11–12—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V11–12—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V11–12—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V7–7—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V12–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V11–12—
Tesla TSP-420420 W43.4 V27.7 V11–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 10 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW10 kW–10 kW95.5%285–500 VYes20240
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

About VOLTRONIC POWER TECHNOLOGY (SHENZHEN)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

InfiniSolar WP LV xKWInfiniSolar WP 12KW OptimumInfiniSolar WP 12KW Premium

Questions & answers

How efficient is the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW?

The California Energy Commission lists a weighted efficiency of 95.5% for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW models, measured at six power levels and three DC voltages.

What sizes does the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW come in?

The CEC list includes 2 models from 10 kW to 10 kW AC: InfiniSolar WP LV 12KW, InfiniSolar WP LV 12KW.

Is the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 12KW be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the InfiniSolar WP LV 12KW’s DC input voltage range?

CEC tested it at 285–500 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).