Cali-GrafCali-Graf
String inverterTesla

Tesla 1538000-xx-y

String inverter. 2 models, 6.66 kW–7.68 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Jan 4, 2021Rapid shutdownInstalled in 74 SoCal permits
Model
  • Rated AC power7.68 kW
  • CEC weighted efficiency98.0%
  • Max DC input600 V
  • Warranty25 years

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · building permits · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SBIn permits
1538000-xx-y6.66 kW208 V6.56 kW6.56 kW97.5%270–480 VJan 4, 2021SB28
1538000-xx-y7.68 kW240 V7.58 kW7.58 kW98.0%270–480 VJan 4, 2021SB28

DC input (PV side)

Tesla datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Tesla datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Tesla datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Tesla datasheet

Monitoring & communication

Tesla datasheet

Panel compatibility & string sizing

Tesla datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
1538000-xx-y: max DC 600 V · MPPT 60–480 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V2–122
REC Group REC460AA Pure-RX460 W68.8 V47.1 V2–82
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V2–12—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V3–15—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V3–15—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V3–14—
Silfab Solar SIL-440QD440 W41.1 V28 V3–14—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V3–14—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V3–14—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V3–15—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V3–14—
Tesla TSP-420420 W43.4 V27.7 V3–13—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Battery & storage pairings

CEC Energy Storage System List · building permits

CEC-certified storage systems that include it

SystemEnergyPowerChemistryCEC listed
Tesla Inc. 1850000-XX-Y13.5 kWh7.6 kWLithium IonMay 3, 2021

Batteries installed with it in SoCal

Tesla Powerwall 2
5
Tesla Powerwall+
5
Tesla Powerwall
4
Tesla Powerwall 3
3

What it's installed with

building permits

Panels

Qcells (model not specified)
8
Qcells Q.PEAK DUO
6
Silfab Solar SIL-xxxHC+
5
Canadian Solar (model not specified)
2
Qcells Q.PEAK
2

Batteries

Tesla Powerwall 2
5
Tesla Powerwall+
5
Tesla Powerwall
4
Tesla Powerwall 3
3

Gateways & interfaces

Tesla Backup Gateway
7
Tesla Backup Switch
2
Permits naming both; 42 of 74 permits list other equipment.

Installed in Southern California

building permits
74
Permits name it
Jul 2021 – Sep 2026
6
Jurisdictions so far
LA County (unincorp.) (55), Palmdale (7), Chula Vista (4), Huntington
7.6 kW
Typical system
median of 44 permits

Permits over time

3Q3 ’2122Q1 ’2226Q3 ’2230Q1 ’2324Q3 ’2332Q1 ’2466Q3 ’2446Q1 ’2554Q3 ’2581Q1 ’2623Q3 ’26permits per quarter

Model named in permit

1538000-xx-y
28

Top ZIP codes

  • ZIP 935516
  • ZIP 912146
  • ZIP 910015
  • ZIP 902654
  • ZIP 917244
  • ZIP 917483
  • ZIP 913903
  • ZIP 917463
  • Other ZIP codes22
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Who installs 1538000-xx-y in SoCal

building permits · CSLB License Master

Compare with similar 7.68 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Tesla 1538000-xx-y6.66 kW–7.68 kW98.0%270–480 VYes202156
GoodWe GEPx.x-1-US304.33 kW–11.4 kW97.0%143–500 VYes2022—
GoodWe GW11K4-MS-US309.88 kW–11.4 kW97.0%217–500 VYes2022—
GoodWe GWxxxx-MS-US304.33 kW–9.6 kW97.0%143–500 VYes2022—
GoodWe GWxxxxA-MS5 kW–9.6 kW97.5%210–480 VYes2021—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Tesla

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

1534000-xx-y · 4 permits

Documents

manufacturer documents

Questions & answers

How efficient is the Tesla 1538000-xx-y?

The California Energy Commission lists a weighted efficiency of 97.5–98.0% for Tesla 1538000-xx-y models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 98.6%.

What sizes does the Tesla 1538000-xx-y come in?

The CEC list includes 2 models from 6.66 kW to 7.68 kW AC: 1538000-xx-y, 1538000-xx-y.

Is the Tesla 1538000-xx-y certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Tesla 1538000-xx-y be used with a battery?

CEC-certified storage systems that include it: Tesla Inc. 1850000-XX-Y. In Southern California permits it was installed with Tesla Powerwall 2, Tesla Powerwall+, Tesla Powerwall.

What is the 1538000-xx-y’s DC input voltage range?

Max DC input voltage is 600 V per the datasheet. MPPT operating range 60–480 V. CEC tested it at 270–480 V DC.

What warranty does it have?

25 years standard (manufacturer datasheet).

Who installs it in Southern California?

Building permits name this series 74 times (Jul 2021 – Sep 2026). The most active licensed installers are Solar Shoppers Construction, A P Electrical, Action Solar.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. California Energy Commission — Energy Storage System List, data as of Oct 7, 2026. Manufacturer-reported values confirmed by CEC against certificates.
  3. Tesla — datasheet Solar Inverter Datasheet (Solar Shutdown Device).
  4. Tesla — document library on the manufacturer’s website (links above).
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  7. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jul 2021 – Jun 2026); City of Palmdale (Mar 2024 – Nov 2025); City of Chula Vista (Mar 2026 – Sep 2026); City of Huntington Beach (Dec 2024 – Oct 2025); LADBS, City of Los Angeles (Dec 2021 – Sep 2022); San Diego County (Jan 2025 – Jul 2025). Equipment matched from permit descriptions by model number.
  9. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).