Cali-GrafCali-Graf
String inverterTesla

Tesla 1534000-xx-y

String inverter. 2 models, 3.34 kW–3.8 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Jan 21, 2021Installed in 4 SoCal permits
Model
  • Rated AC power3.8 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · building permits · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SBIn permits
1534000-xx-y3.34 kW208 V3.34 kW3.34 kW97.5%270–480 VJan 21, 2021SB4
1534000-xx-y3.8 kW240 V3.8 kW3.8 kW97.5%270–425 VJan 21, 2021SB4

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
1534000-xx-y: max DC 425 V · MPPT 270–425 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–10—
Silfab Solar SIL-440QD440 W41.1 V28 V10–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V10–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V10–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V10–10—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Installed in Southern California

building permits
4
Permits name it
Jun 2021 – Jul 2025
1
Jurisdictions so far
LA County (unincorp.) (4)
4.8 kW
Typical system
median of 4 permits

Permits over time

1Q2 ’2100Q4 ’2102Q2 ’2200Q4 ’2200Q2 ’2300Q4 ’2300Q2 ’2400Q4 ’2400Q2 ’251permits per quarter

Model named in permit

1534000-xx-y
4
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 3.8 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Tesla 1534000-xx-y3.34 kW–3.8 kW97.5%270–425 VYes20218
GoodWe GEPx.x-1-US304.33 kW–11.4 kW97.0%143–500 VYes2022—
GoodWe GWxxxx-MS-US304.33 kW–9.6 kW97.0%143–500 VYes2022—
GoodWe GWxxxxA-MS5 kW–9.6 kW97.5%210–480 VYes2021—
ABB UNO-DM-5.0-TL-PLUS-US-SZ-RA-U5 kW–5 kW96.5%200–480 VNo2020—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Tesla

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

1538000-xx-y · 74 permits

Questions & answers

How efficient is the Tesla 1534000-xx-y?

The California Energy Commission lists a weighted efficiency of 97.5% for Tesla 1534000-xx-y models, measured at six power levels and three DC voltages.

What sizes does the Tesla 1534000-xx-y come in?

The CEC list includes 2 models from 3.34 kW to 3.8 kW AC: 1534000-xx-y, 1534000-xx-y.

Is the Tesla 1534000-xx-y certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the 1534000-xx-y’s DC input voltage range?

CEC tested it at 270–425 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jun 2021 – Jul 2025). Equipment matched from permit descriptions by model number.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).