SG200HX-US: max DC 1,500 V · MPPT 850–1,300 V (datasheet)
Most-permitted panels in Southern California
Panel
Power
Voc cold
Vmp hot
Panels per string
Installed together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410
410 W
48.1 V
30.6 V
28–31
—
Qcells Q.PEAK DUO BLK ML-G10+ 410
410 W
48.1 V
30.6 V
28–31
—
LONGi LR5-54HABB-400M
400 W
39.3 V
25.3 V
34–38
—
JA Solar JAM54S31-405/MR
405 W
39.4 V
25.5 V
34–38
—
Hyundai Solutions HiN-T440NF(BK)
440 W
40.9 V
27 V
32–36
—
Silfab Solar SIL-440QD
440 W
41.1 V
28 V
31–36
—
Qcells Q.TRON BLK M-G2+ 430
430 W
41.3 V
28 V
31–36
—
Qcells Q.TRON BLK M-G2.H+ 430
430 W
41.3 V
28 V
31–36
—
REC Group REC460AA Pure-RX
460 W
68.8 V
47.1 V
19–21
—
Elin (Sirius PV) ELNSM54M-HC-410
410 W
39.3 V
25.3 V
34–38
—
Qcells Q.TRON BLK M-G2.C+ 430
430 W
41.3 V
28 V
31–36
—
Tesla TSP-420
420 W
43.4 V
27.7 V
31–34
—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.
Installed in Southern California
building permits
1
Permits name it
Sep 2026
1
Jurisdictions so far
LA County (unincorp.) (1)
1,451.5 kW
Typical system
median of 1 permits
Model named in permit
SG200HX-US
1
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
The California Energy Commission lists a weighted efficiency of 98.5% for Sungrow SGxxxHX-US models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 98.8%.
What sizes does the Sungrow SGxxxHX-US come in?
The CEC list includes 3 models from 200 kW to 350 kW AC: SG200HX-US, SG250HX-US, SG350HX-US.
Is the Sungrow SGxxxHX-US certified to UL 1741 SB?
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for 2 of 4 models.
Can the Sungrow SGxxxHX-US be used with a battery?
The CEC lists it as a dc-coupled hybrid (pv + battery).
What is the SG200HX-US’s DC input voltage range?
Max DC input voltage is 1,500 V per the datasheet. MPPT operating range 500–1,500 V. CEC tested it at 850–1,300 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
Sungrow — document library on the manufacturer’s website (links above).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
California Energy Commission — PV Module List (module electrical data for the compatibility check).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Sep 2026). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.