Cali-GrafCali-Graf
String inverterSungrow

Sungrow SG60CX-US

String inverter. 2 models, 36 kW–60 kW AC at 480 V.

UL 1741 SBCEC listed · Dec 21, 2020Rapid shutdown
Model
  • Rated AC power60 kW
  • CEC weighted efficiency98.0%
  • Max DC input1,000 V

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
SG36CX-US36 kW480 V36 kW36 kW98.0%550–850 VDec 21, 2020SB
SG60CX-US60 kW480 V60.2 kW60.2 kW98.0%550–850 VDec 21, 2020SB

DC input (PV side)

Sungrow datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026) · Sungrow datasheet

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Sungrow datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Sungrow datasheet

Monitoring & communication

Sungrow datasheet

Size, weight & environment

Sungrow datasheet

Panel compatibility & string sizing

Sungrow datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
SG60CX-US: max DC 1,000 V · MPPT 200–1,000 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–20—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–20—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–25—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–25—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V8–24—
Silfab Solar SIL-440QD440 W41.1 V28 V8–24—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V8–24—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V8–24—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–14—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–25—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V8–24—
Tesla TSP-420420 W43.4 V27.7 V8–23—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 60 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Sungrow SGxxCX-US36 kW–60 kW98.0%550–850 VYes20200
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Documents

manufacturer documents

Questions & answers

How efficient is the Sungrow SGxxCX-US?

The California Energy Commission lists a weighted efficiency of 98.0% for Sungrow SGxxCX-US models, measured at six power levels and three DC voltages.

What sizes does the Sungrow SGxxCX-US come in?

The CEC list includes 2 models from 36 kW to 60 kW AC: SG36CX-US, SG60CX-US.

Is the Sungrow SGxxCX-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the SG60CX-US’s DC input voltage range?

Max DC input voltage is 1,000 V per the datasheet. MPPT operating range 200–1,000 V. CEC tested it at 550–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Sungrow — datasheet SG36/60CX-US Datasheet.
  3. Sungrow — document library on the manufacturer’s website (links above).
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  6. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).