Cali-GrafCali-Graf
String inverterSolis (Ginlong Technologies)

Solis (Ginlong Technologies) Solis-60K-US-F-LSW

String inverter. 3 models, 50 kW–66 kW AC at 480 V.

CEC listed · Sep 1, 2020
Model
  • Rated AC power60 kW
  • CEC weighted efficiency98.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 3 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
Solis-50K-US-F-LSW50 kW480 V49.9 kW49.9 kW98.5%568–850 VSep 1, 2020—
Solis-60K-US-F-LSW60 kW480 V59.9 kW59.9 kW98.5%526–850 VSep 1, 2020—
Solis-66K-US-F-LSW66 kW480 V65.9 kW65.9 kW98.5%579–850 VSep 1, 2020—

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
Solis-60K-US-F-LSW: max DC 850 V · MPPT 526–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V21–21—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V21–21—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V20–20—
Silfab Solar SIL-440QD440 W41.1 V28 V19–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V19–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V19–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V21–21—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V19–20—
Tesla TSP-420420 W43.4 V27.7 V19–19—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 60 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Solis (Ginlong Technologies) Solis-xxK-US-F-LSW50 kW–66 kW98.5%526–850 V—20200
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Solis (Ginlong Technologies)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Solis-xxK-5G-US · 3 permitsS5-GC60K-LV-USS6-GC30K-LV-USS6-GUxxxK-EHV-US-M12S6-GUxxxK-EHV-US-M16S5-GCxxK-USS6-GCxxK-USSolis-xxxK-EHV-5G-US-PLUSSolis-xxxK-EHV-5G-USSolis-xxK-US-LSWSolis-xxxK1-EHV-5G

Questions & answers

How efficient is the Solis (Ginlong Technologies) Solis-xxK-US-F-LSW?

The California Energy Commission lists a weighted efficiency of 98.5% for Solis (Ginlong Technologies) Solis-xxK-US-F-LSW models, measured at six power levels and three DC voltages.

What sizes does the Solis (Ginlong Technologies) Solis-xxK-US-F-LSW come in?

The CEC list includes 3 models from 50 kW to 66 kW AC: Solis-50K-US-F-LSW, Solis-60K-US-F-LSW, Solis-66K-US-F-LSW.

Is the Solis (Ginlong Technologies) Solis-xxK-US-F-LSW certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

What is the Solis-60K-US-F-LSW’s DC input voltage range?

CEC tested it at 526–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).