Cali-GrafCali-Graf
Hybrid inverterSolis (Ginlong Technologies)

Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US

Hybrid inverter, dc-coupled hybrid (pv + battery). 2 models, 30 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Oct 1, 2025
Model
  • Rated AC power30 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
S6-EH3P30K03-LV-YD-H-US30 kW208 V25.9 kW25.9 kW97.5%360–850 VOct 1, 2025SB
S6-EH3P30K03-LV-YD-H-US30 kW240 V29.7 kW29.7 kW97.5%360–850 VOct 1, 2025SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
S6-EH3P30K03-LV-YD-H-US: max DC 850 V · MPPT 360–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V12–17—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V12–17—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V15–21—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V15–21—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V14–20—
Silfab Solar SIL-440QD440 W41.1 V28 V13–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V13–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V13–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V8–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V15–21—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V13–20—
Tesla TSP-420420 W43.4 V27.7 V13–19—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 30 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US30 kW–30 kW97.5%360–850 VYes20250
Fortress Power FP-Nano-30k-L25.9 kW–29.8 kW97.0%500–850 VYes2026—
Shenzhen Lux Power Technology GEN-HB-US 25K21.6 kW–25 kW96.5%190–480 VYes2026—
Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US(21A)25.9 kW–29.8 kW97.0%500–850 VYes2026—
Lion Energy Sanctuary 3 Inverter xxkW12 kW–24 kW96.5%150–430 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Approved in other markets

Clean Energy Council (Australia)
ModelApprovedExpiresStandards
S6-EH3P30K-H-AUMay 7, 2025May 7, 2028IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020

About Solis (Ginlong Technologies)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

S6-EH1Px.xK-H-US · 2 permitsS6-EH3P30K03-LV-YD-H-US(21A)S6-EH3P75K10-LV-YD-H-USS6-EH3PxxK03-NV-YD-H-US(21A)S6-EH3PxxK04-NV-YD-H-US(21A)S6-EH3PxxxK10-NV-YD-H-USS6-EH2Px.xK03-SV-YD-L-USS6-EH2PxxK03-SV-YD-L-US-ES6-EH3PxxK03-NV-YD-H-USS6-EH3PxxK04-NV-YD-H-USRHI-1PxK-HVES-5GRHI-1PxK-HVES-xG

Questions & answers

How efficient is the Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US?

The California Energy Commission lists a weighted efficiency of 97.5% for Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US models, measured at six power levels and three DC voltages.

What sizes does the Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US come in?

The CEC list includes 2 models from 30 kW to 30 kW AC: S6-EH3P30K03-LV-YD-H-US, S6-EH3P30K03-LV-YD-H-US.

Is the Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the S6-EH3P30K03-LV-YD-H-US’s DC input voltage range?

CEC tested it at 360–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).