Hybrid inverter, dc-coupled hybrid (pv + battery). 6 models, 3.8 kW–11.4 kW AC at 240 V.
UL 1741 SBCEC listed · Apr 14, 2023Rapid shutdownInstalled in 2 SoCal permits
Model
Rated AC power10 kW
CEC weighted efficiency97.0%
Max DC input600 V
Models & power ratings
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 6 models
Model
Nominal AC
Grid voltage
CEC continuous
Rated AC (SAM)
CEC weighted eff.
DC test window
CEC listed
UL 1741 SB
S6-EH1P3.8K-H-US
3.8 kW
240 V
3.8 kW
3.8 kW
96.5%
140–450 V
Apr 14, 2023
SB
S6-EH1P5K-H-US
5 kW
240 V
5 kW
5 kW
96.5%
140–450 V
Apr 14, 2023
SB
S6-EH1P7.6K-H-US
7.6 kW
240 V
7.6 kW
7.6 kW
97.0%
175–450 V
Apr 14, 2023
SB
S6-EH1P9.9K-H-US
9.9 kW
240 V
9.99 kW
9.99 kW
97.0%
230–450 V
May 21, 2024
SB
S6-EH1P10K-H-US
10 kW
240 V
10 kW
10 kW
97.0%
230–450 V
Apr 14, 2023
SB
S6-EH1P11.4K-H-US
11.4 kW
240 V
11.4 kW
11.4 kW
97.0%
245–450 V
Apr 14, 2023
SB
Some models are also on the CEC Battery Inverter list — one product, two listings.
DC input (PV side)
Solis (Ginlong Technologies) datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
Max DC input voltage600 V
MPPT operating range80–520 V
CEC test DC voltages (min / nom / max)230 / 380 / 450 V
Start-up voltage80 V
Max input current16 A
DC input at rated output (CEC test)10.3 kW
AC output (grid side)
CEC Grid Support Inverter List (Oct 7, 2026) · Solis (Ginlong Technologies) datasheet
Rated AC power10 kW
CEC-measured continuous output10 kW
Grid voltage240 V
Phasesplit-phase 120/240 V
Frequency60 Hz
Efficiency
CEC Grid Support Inverter List (Oct 7, 2026) · Solis (Ginlong Technologies) datasheet · NLR SAM inverter library
CEC weighted efficiency97.0%datasheet: 97.2%
Peak efficiency97.6%
Night-time standby (tare)16.38 W
Power to start converting54.9 W
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.
Grid & smart-inverter certification
CEC Grid Support Inverter List (Oct 7, 2026) · Solis (Ginlong Technologies) datasheet
UL 1741 SB (3rd ed.)Yes — CSA Group, certificate Feb 23, 2024
UL 1741 SA (SA8–SA13)Yes — CSA Group
Firmware tested (SA)A2
Volt-VAr with reactive power priority (SA13)Yes
Freq-Watt / Volt-Watt (SA14–15)Yes
Disable permit service / limit active power (SA17–18)Yes
CSIP (IEEE 2030.5) conformanceVia gateway during testing (Y*)
Monitor key data & scheduling (Rule 21 Phase 3)Yes (attested May 21, 2024)
Power control system (PCS)Stated in CEC listing (power control system)
CEC listedApr 14, 2023
Last CEC updateJun 11, 2025
Standards listed on the datasheetUL 1741 SA, UL 1741, UL 1741 SB, IEEE 1547, UL 1699B, UL 9540, UL 1998, CSA C22.2, FCC Part 15, CA Rule 21, HECO Rule 14H, NEC 690.12 (rapid shutdown)
CEC noteFormerly S6-EH1P7.6K-H-L-US.
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.
InterfacesWi-Fi, Ethernet, RS485, Cellular, Modbus, SunSpec, Bluetooth, CAN
Size, weight & environment
Solis (Ginlong Technologies) datasheet
Dimensions (W × H × D)19.3 × 28.3 × 8.7 in
Enclosure ratingNEMA Type 4X, IP66
CoolingNatural convection (no fans)
Operating temperature−25 to +60 °C
Panel compatibility & string sizing
Solis (Ginlong Technologies) datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
S6-EH1P10K-H-US: max DC 600 V · MPPT 80–520 V (datasheet)
Most-permitted panels in Southern California
Panel
Power
Voc cold
Vmp hot
Panels per string
Installed together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410
410 W
48.1 V
30.6 V
3–12
—
Qcells Q.PEAK DUO BLK ML-G10+ 410
410 W
48.1 V
30.6 V
3–12
—
LONGi LR5-54HABB-400M
400 W
39.3 V
25.3 V
4–15
—
JA Solar JAM54S31-405/MR
405 W
39.4 V
25.5 V
4–15
—
Hyundai Solutions HiN-T440NF(BK)
440 W
40.9 V
27 V
3–14
—
Silfab Solar SIL-440QD
440 W
41.1 V
28 V
3–14
—
Qcells Q.TRON BLK M-G2+ 430
430 W
41.3 V
28 V
3–14
—
Qcells Q.TRON BLK M-G2.H+ 430
430 W
41.3 V
28 V
3–14
—
REC Group REC460AA Pure-RX
460 W
68.8 V
47.1 V
2–8
—
Elin (Sirius PV) ELNSM54M-HC-410
410 W
39.3 V
25.3 V
4–15
—
Qcells Q.TRON BLK M-G2.C+ 430
430 W
41.3 V
28 V
3–14
—
Tesla TSP-420
420 W
43.4 V
27.7 V
3–13
—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.
Battery & storage pairings
building permits
Batteries installed with it in SoCal
Dyness (model not specified)
2
Installed in Southern California
building permits
2
Permits name it
Apr 2025 – Jan 2026
1
Jurisdictions so far
LA County (unincorp.) (2)
7.5 kW
Typical system
median of 2 permits
Model named in permit
S6-EH1P10K-H-US
2
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
Compare with similar 10 kW inverters
CEC Grid Support Inverter List (Oct 7, 2026) · building permits
Inverter
Power
CEC weighted eff.
DC test window
UL 1741 SB
Latest CEC
SoCal permits
Solis (Ginlong Technologies) S6-EH1Px.xK-H-US
3.8 kW–11.4 kW
97.0%
230–450 V
Yes
2024
2
SolarEdge SExxxxH-US
3 kW–11.4 kW
99.0%
360–480 V
Yes
2025
1,046
Delta Electronics Ex-TL-US
3.33 kW–9.6 kW
97.5%
200–480 V
Yes
2022
28
SolarEdge SExxxxxA-US
3.8 kW–11.4 kW
98.0%
320–500 V
No
2024
18
Growatt MIN xxxxTL-XH-US
2.63 kW–11.4 kW
98.0%
125–480 V
Yes
2021
15
Same type and grid voltage, power range covering this model; same fields from the same sources.
How efficient is the Solis (Ginlong Technologies) S6-EH1Px.xK-H-US?
The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Solis (Ginlong Technologies) S6-EH1Px.xK-H-US models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 97.6%.
What sizes does the Solis (Ginlong Technologies) S6-EH1Px.xK-H-US come in?
The CEC list includes 6 models from 3.8 kW to 11.4 kW AC: S6-EH1P3.8K-H-US, S6-EH1P5K-H-US, S6-EH1P7.6K-H-US, S6-EH1P9.9K-H-US, S6-EH1P10K-H-US, S6-EH1P11.4K-H-US.
Is the Solis (Ginlong Technologies) S6-EH1Px.xK-H-US certified to UL 1741 SB?
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
Can the Solis (Ginlong Technologies) S6-EH1Px.xK-H-US be used with a battery?
The CEC lists it as a dc-coupled hybrid (pv + battery). In Southern California permits it was installed with Dyness (model not specified).
What is the S6-EH1P10K-H-US’s DC input voltage range?
Max DC input voltage is 600 V per the datasheet. MPPT operating range 80–520 V. CEC tested it at 230–450 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
Solis (Ginlong Technologies) — manufacturer datasheet “GINLONG TECHNOLOGIES CO.,LTD. S6-EH1P(3.8-11.4)K-H-US”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
California Energy Commission — PV Module List (module electrical data for the compatibility check).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Apr 2025 – Jan 2026). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.