Cali-GrafCali-Graf
String inverterSolis (Ginlong Technologies)

Solis (Ginlong Technologies) S5-GC60K-LV-US

String inverter. 2 models, 60 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Dec 23, 2024
Model
  • Rated AC power60 kW
  • CEC weighted efficiency98.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
S5-GC60K-LV-US60 kW208 V60 kW60 kW98.0%400–650 VDec 23, 2024SB
S5-GC60K-LV-US60 kW240 V60 kW60 kW98.0%400–650 VAug 21, 2025SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
S5-GC60K-LV-US: max DC 650 V · MPPT 400–650 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V16–16—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V16–16—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V15–15—
Silfab Solar SIL-440QD440 W41.1 V28 V15–15—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V15–15—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V15–15—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V9–9—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V16–16—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V15–15—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

About Solis (Ginlong Technologies)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Solis-xxK-5G-US · 3 permitsS6-GC30K-LV-USS6-GUxxxK-EHV-US-M12S6-GUxxxK-EHV-US-M16S5-GCxxK-USS6-GCxxK-USSolis-xxxK-EHV-5G-US-PLUSSolis-xxxK-EHV-5G-USSolis-xxK-US-F-LSWSolis-xxK-US-LSWSolis-xxxK1-EHV-5G

Questions & answers

How efficient is the Solis (Ginlong Technologies) S5-GC60K-LV-US?

The California Energy Commission lists a weighted efficiency of 98.0% for Solis (Ginlong Technologies) S5-GC60K-LV-US models, measured at six power levels and three DC voltages.

What sizes does the Solis (Ginlong Technologies) S5-GC60K-LV-US come in?

The CEC list includes 2 models from 60 kW to 60 kW AC: S5-GC60K-LV-US, S5-GC60K-LV-US.

Is the Solis (Ginlong Technologies) S5-GC60K-LV-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the S5-GC60K-LV-US’s DC input voltage range?

CEC tested it at 400–650 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).