Cali-GrafCali-Graf
Hybrid inverterSolis (Ginlong Technologies)

Solis (Ginlong Technologies) RHI-1P8K-HVES-5G

Hybrid inverter, dc-coupled hybrid (pv + battery). 6 models, 6 kW–10 kW AC at 240 V.

CEC listed · Apr 13, 2020Rapid shutdown
Model
  • Rated AC power8 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 6 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
RHI-1P6K-HVES-5G6 kW240 V6 kW6 kW97.5%130–450 VApr 13, 2020—
RHI-1P7K-HVES-5G7 kW240 V7.01 kW7.01 kW97.5%160–450 VApr 13, 2020—
RHI-1P7.6K-HVES-5G7.6 kW240 V7.6 kW7.6 kW97.5%175–450 VApr 13, 2020—
RHI-1P8K-HVES-5G8 kW240 V8.01 kW8.01 kW97.5%185–450 VApr 13, 2020—
RHI-1P9K-HVES-5G9 kW240 V9.01 kW9.01 kW97.5%210–450 VApr 13, 2020—
RHI-1P10K-HVES-5G10 kW240 V10 kW10 kW97.5%230–450 VApr 13, 2020—
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Solis (Ginlong Technologies) datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Backup power

Safety & protection

Solis (Ginlong Technologies) datasheet

Monitoring & communication

Solis (Ginlong Technologies) datasheet

Size, weight & environment

Solis (Ginlong Technologies) datasheet

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
RHI-1P8K-HVES-5G: max DC 450 V · MPPT 185–450 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–11—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–11—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V7–10—
Silfab Solar SIL-440QD440 W41.1 V28 V7–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V7–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V7–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V4–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–11—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V7–10—
Tesla TSP-420420 W43.4 V27.7 V7–10—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 8 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Solis (Ginlong Technologies) RHI-1PxK-HVES-5G6 kW–10 kW97.5%185–450 V—20200
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
Qcells Q.VOLT Hx.xSX3.8 kW–7.6 kW97.5%175–500 VYes202325
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Solis (Ginlong Technologies)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

S6-EH1Px.xK-H-US · 2 permitsS6-EH3P30K03-LV-YD-H-US(21A)S6-EH3P75K10-LV-YD-H-USS6-EH3PxxK03-NV-YD-H-US(21A)S6-EH3PxxK04-NV-YD-H-US(21A)S6-EH3PxxxK10-NV-YD-H-USS6-EH2Px.xK03-SV-YD-L-USS6-EH2PxxK03-SV-YD-L-US-ES6-EH3P30K03-LV-YD-H-USS6-EH3PxxK03-NV-YD-H-USS6-EH3PxxK04-NV-YD-H-USRHI-1PxK-HVES-xG

Questions & answers

How efficient is the Solis (Ginlong Technologies) RHI-1PxK-HVES-5G?

The California Energy Commission lists a weighted efficiency of 97.5% for Solis (Ginlong Technologies) RHI-1PxK-HVES-5G models, measured at six power levels and three DC voltages.

What sizes does the Solis (Ginlong Technologies) RHI-1PxK-HVES-5G come in?

The CEC list includes 6 models from 6 kW to 10 kW AC: RHI-1P6K-HVES-5G, RHI-1P7K-HVES-5G, RHI-1P7.6K-HVES-5G, RHI-1P8K-HVES-5G, RHI-1P9K-HVES-5G, RHI-1P10K-HVES-5G.

Is the Solis (Ginlong Technologies) RHI-1PxK-HVES-5G certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

Can the Solis (Ginlong Technologies) RHI-1PxK-HVES-5G be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the RHI-1P8K-HVES-5G’s DC input voltage range?

CEC tested it at 185–450 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Solis (Ginlong Technologies) — manufacturer datasheet “RHI-1P(5-10)K-HVES-5G Solis PV Storage Inverter Model:”.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).