Cali-GrafCali-Graf
Hybrid inverterSol-Ark

Sol-Ark 12K-2P-LL

Hybrid inverter, dc-coupled hybrid (pv + battery). 2 models, 12 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Aug 11, 2026Rapid shutdown
Model
  • Rated AC power12 kW
  • CEC weighted efficiency97.0%
  • Warranty10 years

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · 2 models
ModelNominal ACGrid voltageCEC continuousCEC weighted eff.DC test windowCEC listedUL 1741 SB
12K-2P-LL12 kW208 V12 kW97.5%250–425 VAug 11, 2026SB
12K-2P-LL12 kW240 V12 kW97.0%250–425 VAug 11, 2026SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

Sol-Ark datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

AC output (grid side)

Sol-Ark datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Sol-Ark datasheet
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Sol-Ark datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Sol-Ark datasheet

Monitoring & communication

Sol-Ark datasheet

Size, weight & environment

Sol-Ark datasheet

Panel compatibility & string sizing

CEC Grid Support Inverter List (Oct 7, 2026) · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
12K-2P-LL: max DC 425 V · MPPT 250–425 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–10—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–10—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–10—
Silfab Solar SIL-440QD440 W41.1 V28 V9–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–10—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–10—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 12 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Sol-Ark 12K-2P-LL12 kW–12 kW97.0%250–425 VYes20260
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Sol-Ark

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Limitless 18K-2P-LVLimitless xxK-LVxxK-3P-480VxxK-3P-208V5K-120V/8K-230V-1P

Documents

manufacturer documents

Questions & answers

How efficient is the Sol-Ark 12K-2P-LL?

The California Energy Commission lists a weighted efficiency of 97.0–97.5% for Sol-Ark 12K-2P-LL models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 97.6%.

What sizes does the Sol-Ark 12K-2P-LL come in?

The CEC list includes 2 models from 12 kW to 12 kW AC: 12K-2P-LL, 12K-2P-LL.

Is the Sol-Ark 12K-2P-LL certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Sol-Ark 12K-2P-LL be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the 12K-2P-LL’s DC input voltage range?

CEC tested it at 250–425 V DC.

What warranty does it have?

10 years standard (manufacturer datasheet).

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Sol-Ark — datasheet SA-12K-2P-LL Datasheet Rev1.1 PS-00045.
  3. Sol-Ark — document library on the manufacturer’s website (links above).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).