String inverter. 4 models, 27.5 kW–70 kW AC at 208 V / 480 V.
| Model | Nominal AC | Grid voltage | CEC continuous | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|
| STP 27-US-80 | 27.5 kW | 208 V | 26.8 kW | 97.0% | 300–800 V | Aug 21, 2026 | SB |
| STP 50-US-80 | 50 kW | 480 V | 50 kW | 97.5% | 500–850 V | Aug 21, 2026 | SB |
| STP 62-US-80 | 62.5 kW | 480 V | 62.5 kW | 97.5% | 500–850 V | Aug 21, 2026 | SB |
| STP 70-US-80 | 70 kW | 480 V | 70 kW | 97.5% | 500–850 V | Aug 21, 2026 | SB |
| Panel | Power | Voc cold | Vmp hot | Panels per string | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 V | 30.6 V | 17–17 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 V | 30.6 V | 17–17 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 V | 25.3 V | 20–21 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 V | 25.5 V | 20–21 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 V | 27 V | 19–20 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 V | 28 V | 18–20 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 V | 28 V | 18–20 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 V | 28 V | 18–20 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 V | 47.1 V | 11–12 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 V | 25.3 V | 20–21 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 V | 28 V | 18–20 | — |
| Tesla TSP-420 | 420 W | 43.4 V | 27.7 V | 19–19 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| SMA STP xx-US-80 | 27.5 kW–70 kW | 97.5% | 500–850 V | Yes | 2026 | 0 |
| SolarEdge SExKUS | 9 kW–330 kW | 99.0% | 100–1,400 V | 16 of 19 | 2025 | 14 |
| CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480 | 36 kW–60 kW | 98.5% | 400–850 V | Yes | 2023 | 3 |
| Solis (Ginlong Technologies) Solis-xxK-5G-US | 75 kW–100 kW | 98.5% | 550–850 V | No | 2020 | 3 |
| Yaskawa Solectria Solar PVI xxTL-480 | 36 kW–100 kW | 98.5% | 340–850 V | 3 of 4 | 2025 | — |
The California Energy Commission lists a weighted efficiency of 97.0–97.5% for SMA STP xx-US-80 models, measured at six power levels and three DC voltages.
The CEC list includes 4 models from 27.5 kW to 70 kW AC: STP 27-US-80, STP 50-US-80, STP 62-US-80, STP 70-US-80.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
CEC tested it at 500–850 V DC.