Cali-GrafCali-Graf
String inverterSMA

SMA STP 62-US-80

String inverter. 4 models, 27.5 kW–70 kW AC at 208 V / 480 V.

UL 1741 SBCEC listed · Aug 21, 2026
Model
  • Rated AC power62.5 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · 4 models
ModelNominal ACGrid voltageCEC continuousCEC weighted eff.DC test windowCEC listedUL 1741 SB
STP 27-US-8027.5 kW208 V26.8 kW97.0%300–800 VAug 21, 2026SB
STP 50-US-8050 kW480 V50 kW97.5%500–850 VAug 21, 2026SB
STP 62-US-8062.5 kW480 V62.5 kW97.5%500–850 VAug 21, 2026SB
STP 70-US-8070 kW480 V70 kW97.5%500–850 VAug 21, 2026SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026)
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

CEC Grid Support Inverter List (Oct 7, 2026) · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
STP 62-US-80: max DC 850 V · MPPT 500–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V17–17—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V17–17—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V20–21—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V20–21—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V19–20—
Silfab Solar SIL-440QD440 W41.1 V28 V18–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V18–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V18–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V11–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V20–21—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V18–20—
Tesla TSP-420420 W43.4 V27.7 V19–19—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 62.5 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
SMA STP xx-US-8027.5 kW–70 kW97.5%500–850 VYes20260
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
Yaskawa Solectria Solar PVI xxTL-48036 kW–100 kW98.5%340–850 V3 of 42025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About SMA

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

SHP FLEX-US-21STP xx-US-50SHP xxx-US-21

Questions & answers

How efficient is the SMA STP xx-US-80?

The California Energy Commission lists a weighted efficiency of 97.0–97.5% for SMA STP xx-US-80 models, measured at six power levels and three DC voltages.

What sizes does the SMA STP xx-US-80 come in?

The CEC list includes 4 models from 27.5 kW to 70 kW AC: STP 27-US-80, STP 50-US-80, STP 62-US-80, STP 70-US-80.

Is the SMA STP xx-US-80 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the STP 62-US-80’s DC input voltage range?

CEC tested it at 500–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  3. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  4. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).