String inverter. 4 models, 13 kW–30 kW AC at 208 V / 480 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| STP 13-US-50 | 13 kW | 208 V | 13 kW | 13 kW | 97.0% | 230–640 V | Sep 11, 2025 | SB |
| STP 20-US-50 | 20 kW | 480 V | 20 kW | 20 kW | 97.5% | 350–800 V | Sep 1, 2023 | SB |
| STP 25-US-50 | 25 kW | 480 V | 25 kW | 25 kW | 98.0% | 430–800 V | Sep 1, 2023 | SB |
| STP 30-US-50 | 30 kW | 480 V | 30 kW | 30 kW | 98.0% | 515–800 V | Sep 1, 2023 | SB |
| Panel | Power | Voc cold | Vmp hot | Panels per string | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 V | 30.6 V | 15–16 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 V | 30.6 V | 15–16 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 V | 25.3 V | 17–20 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 V | 25.5 V | 17–20 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 V | 27 V | 16–19 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 V | 28 V | 16–19 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 V | 28 V | 16–19 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 V | 28 V | 16–19 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 V | 47.1 V | 10–11 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 V | 25.3 V | 17–20 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 V | 28 V | 16–19 | — |
| Tesla TSP-420 | 420 W | 43.4 V | 27.7 V | 16–18 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| SMA STP xx-US-50 | 13 kW–30 kW | 98.0% | 430–800 V | Yes | 2025 | 0 |
| SolarEdge SExKUS | 9 kW–330 kW | 99.0% | 100–1,400 V | 16 of 19 | 2025 | 14 |
| CPS (Chint Power Systems) CPS SCAxxKTL-DO-R/US-480 | 20 kW–25 kW | 98.0% | 560–850 V | Yes | 2020 | 1 |
| SMA STP xx-US-80 | 27.5 kW–70 kW | 97.5% | 300–850 V | Yes | 2026 | — |
| Canadian Solar CSI-xxK-T480GL03-U | 25 kW–100 kW | 98.5% | 550–850 V | Yes | 2024 | — |
The California Energy Commission lists a weighted efficiency of 97.0–98.0% for SMA STP xx-US-50 models, measured at six power levels and three DC voltages.
The CEC list includes 4 models from 13 kW to 30 kW AC: STP 13-US-50, STP 20-US-50, STP 25-US-50, STP 30-US-50.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
CEC tested it at 430–800 V DC.