String inverterSMA

SMA SHP 165-US-21

String inverter. 4 models, 125 kW–172 kW AC at 480 V / 600 V / 630 V / 660 V.

UL 1741 SBCEC listed · Mar 21, 2023
Model
  • Rated AC power165 kW
  • CEC weighted efficiency99.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
SHP 125-US-21125 kW480 V125 kW125 kW98.5%705–1,200 VJul 11, 2023SB
SHP 150-US-21150 kW600 V150 kW150 kW99.0%880–1,200 VMar 21, 2023SB
SHP 165-US-21165 kW630 V165 kW165 kW99.0%925–1,200 VMar 21, 2023SB
SHP 172-US-21172 kW660 V172 kW172 kW99.0%968–1,200 VMar 21, 2023SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
SHP 165-US-21: max DC 1,200 V · MPPT 925–1,200 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 165 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
SMA SHP xxx-US-21125 kW–172 kW99.0%925–1,200 VYes20230
SMA SHP FLEX-US-2155 kW–172 kW99.0%372–1,200 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About SMA

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

STP xx-US-80SHP FLEX-US-21STP xx-US-50

Questions & answers

How efficient is the SMA SHP xxx-US-21?

The California Energy Commission lists a weighted efficiency of 98.5–99.0% for SMA SHP xxx-US-21 models, measured at six power levels and three DC voltages.

What sizes does the SMA SHP xxx-US-21 come in?

The CEC list includes 4 models from 125 kW to 172 kW AC: SHP 125-US-21, SHP 150-US-21, SHP 165-US-21, SHP 172-US-21.

Is the SMA SHP xxx-US-21 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the SHP 165-US-21’s DC input voltage range?

CEC tested it at 925–1,200 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).