Cali-GrafCali-Graf
Hybrid inverterShenzhen Megarevo Technology

Shenzhen Megarevo Technology R12KLNA-P6

Hybrid inverter, dc-coupled hybrid (pv + battery). 3 models, 8 kW–16 kW AC at 240 V.

UL 1741 SBCEC listed · Nov 21, 2024
Model
  • Rated AC power12 kW
  • CEC weighted efficiency96.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 3 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
R8KLNA-P68 kW240 V8.18 kW8.18 kW96.5%150–430 VNov 21, 2024SB
R12KLNA-P612 kW240 V12.2 kW12.2 kW96.5%200–430 VNov 21, 2024SB
R16KLNA-P616 kW240 V16.2 kW16.2 kW96.5%220–430 VNov 21, 2024SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
R12KLNA-P6: max DC 430 V · MPPT 200–430 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–8—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–8—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–10—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–10—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V8–10—
Silfab Solar SIL-440QD440 W41.1 V28 V8–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V8–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V8–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–10—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V8–10—
Tesla TSP-420420 W43.4 V27.7 V8–9—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 12 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Shenzhen Megarevo Technology RxKLNA-P68 kW–16 kW96.5%200–430 VYes20240
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Shenzhen Megarevo Technology

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

RxKLNA · 1 permitsRxKH1NARxKLNA-P4RxxK4H1NARxxLNA-P4RxK6LNA

Questions & answers

How efficient is the Shenzhen Megarevo Technology RxKLNA-P6?

The California Energy Commission lists a weighted efficiency of 96.5% for Shenzhen Megarevo Technology RxKLNA-P6 models, measured at six power levels and three DC voltages.

What sizes does the Shenzhen Megarevo Technology RxKLNA-P6 come in?

The CEC list includes 3 models from 8 kW to 16 kW AC: R8KLNA-P6, R12KLNA-P6, R16KLNA-P6.

Is the Shenzhen Megarevo Technology RxKLNA-P6 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Shenzhen Megarevo Technology RxKLNA-P6 be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the R12KLNA-P6’s DC input voltage range?

CEC tested it at 200–430 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).