Cali-GrafCali-Graf
Hybrid inverterPhaseGreen Technology

PhaseGreen Technology PhG-P8K0LNA-M

Hybrid inverter, dc-coupled hybrid (pv + battery). 4 models, 5 kW–10 kW AC at 240 V.

UL 1741 SBCEC listed · May 11, 2023Installed in 2 SoCal permits
Model
  • Rated AC power8 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
PhG-P5K0LNA-M5 kW240 V5.09 kW5.09 kW97.0%180–430 VMay 11, 2023SB
PhG-P6K0LNA-M6 kW240 V6.12 kW6.12 kW97.0%200–430 VMay 11, 2023SB
PhG-P8K0LNA-M8 kW240 V8.08 kW8.08 kW97.5%250–430 VMay 11, 2023SB
PhG-P10K0LNA-M10 kW240 V10.2 kW10.2 kW97.0%280–430 VMay 11, 2023SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
PhG-P8K0LNA-M: max DC 430 V · MPPT 250–430 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–10—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–10—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–10—
Silfab Solar SIL-440QD440 W41.1 V28 V9–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–10—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–10—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Installed in Southern California

building permits
2
Permits name it
Jun 2023 – Aug 2023
1
Jurisdictions so far
LA County (unincorp.) (2)
8.5 kW
Typical system
median of 1 permits

Model named in permit

PhG-P8K0LNA-M
2
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 8 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
PhaseGreen Technology PhG-PxK0LNA-M5 kW–10 kW97.5%250–430 VYes20232
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
Qcells Q.VOLT Hx.xSX3.8 kW–7.6 kW97.5%175–500 VYes202325
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Same type and grid voltage, power range covering this model; same fields from the same sources.

About PhaseGreen Technology

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PhG-PxK6LNA-M

Questions & answers

How efficient is the PhaseGreen Technology PhG-PxK0LNA-M?

The California Energy Commission lists a weighted efficiency of 97.0–97.5% for PhaseGreen Technology PhG-PxK0LNA-M models, measured at six power levels and three DC voltages.

What sizes does the PhaseGreen Technology PhG-PxK0LNA-M come in?

The CEC list includes 4 models from 5 kW to 10 kW AC: PhG-P5K0LNA-M, PhG-P6K0LNA-M, PhG-P8K0LNA-M, PhG-P10K0LNA-M.

Is the PhaseGreen Technology PhG-PxK0LNA-M certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the PhaseGreen Technology PhG-PxK0LNA-M be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the PhG-P8K0LNA-M’s DC input voltage range?

CEC tested it at 250–430 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jun 2023 – Aug 2023). Equipment matched from permit descriptions by model number.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).