String inverter. 9 models, 25 kW–100 kW AC at 480 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| Neptune25K | 25 kW | 480 V | 24.9 kW | 24.9 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune30K | 30 kW | 480 V | 29.9 kW | 29.9 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune33K | 33 kW | 480 V | 32.9 kW | 32.9 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune36K | 36 kW | 480 V | 35.9 kW | 35.9 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune40K | 40 kW | 480 V | 39.8 kW | 39.8 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune50K | 50 kW | 480 V | 49.8 kW | 49.8 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune60K | 60 kW | 480 V | 59.9 kW | 59.9 kW | 98.5% | 580–850 V | Feb 12, 2024 | SB |
| Neptune75K | 75 kW | 480 V | 74.6 kW | 74.6 kW | 98.5% | 550–850 V | Mar 1, 2024 | SB |
| Neptune100K | 100 kW | 480 V | 99.4 kW | 99.4 kW | 98.0% | 550–850 V | Mar 1, 2024 | SB |
| Panel | Power | Voc cold | Vmp hot | Panels per string | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 V | 30.6 V | no fit | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 V | 30.6 V | no fit | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 V | 25.3 V | no fit | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 V | 25.5 V | no fit | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 V | 27 V | no fit | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 V | 28 V | no fit | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 V | 28 V | no fit | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 V | 28 V | no fit | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 V | 47.1 V | no fit | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 V | 25.3 V | no fit | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 V | 28 V | no fit | — |
| Tesla TSP-420 | 420 W | 43.4 V | 27.7 V | no fit | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Northern Electric & Power NeptunexxK | 25 kW–100 kW | 98.5% | 580–850 V | Yes | 2024 | 0 |
| SolarEdge SExKUS | 9 kW–330 kW | 99.0% | 100–1,400 V | 16 of 19 | 2025 | 14 |
| CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480 | 36 kW–60 kW | 98.5% | 400–850 V | Yes | 2023 | 3 |
| SMA STP xx-US-80 | 27.5 kW–70 kW | 97.5% | 300–850 V | Yes | 2026 | — |
| Yaskawa Solectria Solar PVI xxTL-480 | 36 kW–100 kW | 98.5% | 340–850 V | 3 of 4 | 2025 | — |
The California Energy Commission lists a weighted efficiency of 98.0–98.5% for Northern Electric & Power NeptunexxK models, measured at six power levels and three DC voltages.
The CEC list includes 9 models from 25 kW to 100 kW AC: Neptune25K, Neptune30K, Neptune33K, Neptune36K, Neptune40K, Neptune50K, Neptune60K, Neptune75K….
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
CEC tested it at 580–850 V DC.