Hybrid inverter, dc-coupled hybrid (pv + battery). 1 model, 800 kW AC at 800 V.
UL 1741 SBCEC listed · May 11, 2023
Rated AC power800 kW
CEC weighted efficiency98.0%
DC input (PV side)
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC test DC voltages (min / nom / max)1,200 / 1,350 / 1,500 V
DC input at rated output (CEC test)818.1 kW
AC output (grid side)
CEC Grid Support Inverter List (Oct 7, 2026)
Rated AC power800 kW
CEC-measured continuous output801.4 kW
Grid voltage800 V
Phase3-phase 800 V
Efficiency
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency98.0%
Night-time standby (tare)222.84 W
Power to start converting2,132.4 W
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.
Grid & smart-inverter certification
CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB (3rd ed.)Yes — Intertek, certificate Nov 4, 2022
UL 1741 SA (SA8–SA13)No
Volt-VAr with reactive power priority (SA13)No
Freq-Watt / Volt-Watt (SA14–15)No
Disable permit service / limit active power (SA17–18)No
CSIP (IEEE 2030.5) conformanceNo
Monitor key data & scheduling (Rule 21 Phase 3)No
CEC listedMay 11, 2023
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.
Panel compatibility & string sizing
NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
NXPCS800K-HUD: max DC 1,500 V · MPPT 1,200–1,500 V (CEC test window)
Most-permitted panels in Southern California
Panel
Power
Voc cold
Vmp hot
Panels per string
Installed together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410
410 W
48.1 V
30.6 V
no fit
—
Qcells Q.PEAK DUO BLK ML-G10+ 410
410 W
48.1 V
30.6 V
no fit
—
LONGi LR5-54HABB-400M
400 W
39.3 V
25.3 V
no fit
—
JA Solar JAM54S31-405/MR
405 W
39.4 V
25.5 V
no fit
—
Hyundai Solutions HiN-T440NF(BK)
440 W
40.9 V
27 V
no fit
—
Silfab Solar SIL-440QD
440 W
41.1 V
28 V
no fit
—
Qcells Q.TRON BLK M-G2+ 430
430 W
41.3 V
28 V
no fit
—
Qcells Q.TRON BLK M-G2.H+ 430
430 W
41.3 V
28 V
no fit
—
REC Group REC460AA Pure-RX
460 W
68.8 V
47.1 V
no fit
—
Elin (Sirius PV) ELNSM54M-HC-410
410 W
39.3 V
25.3 V
no fit
—
Qcells Q.TRON BLK M-G2.C+ 430
430 W
41.3 V
28 V
no fit
—
Tesla TSP-420
420 W
43.4 V
27.7 V
no fit
—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.
Questions & answers
How efficient is the NEXTRACKER NXPCSxxxK-HUD?
The California Energy Commission lists a weighted efficiency of 98.0% for NEXTRACKER NXPCSxxxK-HUD models, measured at six power levels and three DC voltages.
Is the NEXTRACKER NXPCSxxxK-HUD certified to UL 1741 SB?
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
Can the NEXTRACKER NXPCSxxxK-HUD be used with a battery?
The CEC lists it as a dc-coupled hybrid (pv + battery).
What is the NXPCS800K-HUD’s DC input voltage range?
CEC tested it at 1,200–1,500 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
California Energy Commission — PV Module List (module electrical data for the compatibility check).
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.