Cali-GrafCali-Graf
Hybrid inverterLion Energy

Lion Energy Lion Hybrid Inverter 15kW

Hybrid inverter, dc-coupled hybrid (pv + battery). 2 models, 12 kW–15 kW AC at 240 V.

UL 1741 SBCEC listed · Sep 22, 2025
Model
  • Rated AC power15 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
Lion Hybrid Inverter 12kW12 kW240 V8.08 kW8.08 kW97.5%250–430 VSep 22, 2025SB
Lion Hybrid Inverter 15kW15 kW240 V10.2 kW10.2 kW97.0%280–430 VSep 22, 2025SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
Lion Hybrid Inverter 15kW: max DC 430 V · MPPT 280–430 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 15 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Lion Energy Lion Hybrid Inverter xxkW12 kW–15 kW97.0%280–430 VYes20250
EG4 Electronics 18KPV-12LV10.4 kW–12 kW97.0%230–480 VYes20237
Shenzhen Lux Power Technology LXP-LB-US xK8 kW–16 kW97.0%210–480 VYes20251
Sol-Ark 12K-2P-LL12 kW–12 kW97.5%250–425 VYes2026—
Suzhou Ample ESS AP-LxK-SPUS7.98 kW–15 kW96.5%108–480 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Lion Energy

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Sanctuary 3 Inverter xxkW#50170167 Sanctuary 8K

Questions & answers

How efficient is the Lion Energy Lion Hybrid Inverter xxkW?

The California Energy Commission lists a weighted efficiency of 97.0–97.5% for Lion Energy Lion Hybrid Inverter xxkW models, measured at six power levels and three DC voltages.

What sizes does the Lion Energy Lion Hybrid Inverter xxkW come in?

The CEC list includes 2 models from 12 kW to 15 kW AC: Lion Hybrid Inverter 12kW, Lion Hybrid Inverter 15kW.

Is the Lion Energy Lion Hybrid Inverter xxkW certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Lion Energy Lion Hybrid Inverter xxkW be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the Lion Hybrid Inverter 15kW’s DC input voltage range?

CEC tested it at 280–430 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).