String inverterKACO new energy

KACO new energy KACO blueplanet 137 TL3 M1 WM OD IIP0

String inverter. 2 models, 125 kW–137 kW AC at 600 V.

CEC listed · Feb 11, 2020
Model
  • Rated AC power137 kW
  • CEC weighted efficiency99.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
KACO blueplanet 125 TL3 M1 WM OD IIP0125 kW600 V138.7 kW138.7 kW99.0%875–1,300 VFeb 11, 2020—
KACO blueplanet 137 TL3 M1 WM OD IIP0137 kW600 V138.7 kW138.7 kW99.0%875–1,300 VFeb 11, 2020—

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
KACO blueplanet 137 TL3 M1 WM OD IIP0: max DC 1,300 V · MPPT 875–1,300 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 137 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
KACO new energy KACO blueplanet xxx TL3 M1 WM OD IIP0125 kW–137 kW99.0%875–1,300 V—20200
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
SMA SHP FLEX-US-2155 kW–172 kW99.0%372–1,200 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About KACO new energy

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

KACO blueplanet xxx TL3 M1 WM OD IIK0KACO blueplanet xxx TL3 M1 WM OD IIKXKACO blueplanet xxx TL3 M1 WM OD IIPXKACO blueplanet xxx TL3 M1 WM OD IIQ0KACO blueplanet xxx TL3 M1 WM OD IIQX

Questions & answers

How efficient is the KACO new energy KACO blueplanet xxx TL3 M1 WM OD IIP0?

The California Energy Commission lists a weighted efficiency of 99.0% for KACO new energy KACO blueplanet xxx TL3 M1 WM OD IIP0 models, measured at six power levels and three DC voltages.

What sizes does the KACO new energy KACO blueplanet xxx TL3 M1 WM OD IIP0 come in?

The CEC list includes 2 models from 125 kW to 137 kW AC: KACO blueplanet 125 TL3 M1 WM OD IIP0, KACO blueplanet 137 TL3 M1 WM OD IIP0.

Is the KACO new energy KACO blueplanet xxx TL3 M1 WM OD IIP0 certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

What is the KACO blueplanet 137 TL3 M1 WM OD IIP0’s DC input voltage range?

CEC tested it at 875–1,300 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).