Disable permit service / limit active power (SA17–18)No
CSIP (IEEE 2030.5) conformanceVia gateway during testing (Y*)
Monitor key data & scheduling (Rule 21 Phase 3)Yes (attested Feb 21, 2025)
Power control system (PCS)Stated in CEC listing (power control system)
CEC listedFeb 21, 2025
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.
Panel compatibility & string sizing
NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
GVI-HR-11K4-USG: max DC 450 V · MPPT 245–450 V (CEC test window)
Most-permitted panels in Southern California
Panel
Power
Voc cold
Vmp hot
Panels per string
Installed together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410
410 W
48.1 V
30.6 V
8–9
—
Qcells Q.PEAK DUO BLK ML-G10+ 410
410 W
48.1 V
30.6 V
8–9
—
LONGi LR5-54HABB-400M
400 W
39.3 V
25.3 V
10–11
—
JA Solar JAM54S31-405/MR
405 W
39.4 V
25.5 V
10–11
—
Hyundai Solutions HiN-T440NF(BK)
440 W
40.9 V
27 V
10–10
—
Silfab Solar SIL-440QD
440 W
41.1 V
28 V
9–10
—
Qcells Q.TRON BLK M-G2+ 430
430 W
41.3 V
28 V
9–10
—
Qcells Q.TRON BLK M-G2.H+ 430
430 W
41.3 V
28 V
9–10
—
REC Group REC460AA Pure-RX
460 W
68.8 V
47.1 V
6–6
—
Elin (Sirius PV) ELNSM54M-HC-410
410 W
39.3 V
25.3 V
10–11
—
Qcells Q.TRON BLK M-G2.C+ 430
430 W
41.3 V
28 V
9–10
—
Tesla TSP-420
420 W
43.4 V
27.7 V
9–10
—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.
Compare with similar 11.4 kW inverters
CEC Grid Support Inverter List (Oct 7, 2026) · building permits
Inverter
Power
CEC weighted eff.
DC test window
UL 1741 SB
Latest CEC
SoCal permits
Jackery GVI-HR-xxK4-USG
11.4 kW–11.4 kW
97.0%
245–450 V
Yes
2025
0
SolarEdge SExxxxH-US
3 kW–11.4 kW
99.0%
360–480 V
Yes
2025
1,046
Delta Electronics Ex-TL-US
3.33 kW–9.6 kW
97.5%
200–480 V
Yes
2022
28
SolarEdge SExxxxxA-US
3.8 kW–11.4 kW
98.0%
320–500 V
No
2024
18
Growatt MIN xxxxTL-XH-US
2.63 kW–11.4 kW
98.0%
125–480 V
Yes
2021
15
Same type and grid voltage, power range covering this model; same fields from the same sources.
About Jackery
CEC Grid Support Inverter List (Oct 7, 2026)
ManufacturerJackery
Listed in CEC asJackery Inc.
Models on CEC lists16
Other series
GVI-HR-xK6-USG
Questions & answers
How efficient is the Jackery GVI-HR-xxK4-USG?
The California Energy Commission lists a weighted efficiency of 97.0% for Jackery GVI-HR-xxK4-USG models, measured at six power levels and three DC voltages.
Is the Jackery GVI-HR-xxK4-USG certified to UL 1741 SB?
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
Can the Jackery GVI-HR-xxK4-USG be used with a battery?
The CEC lists it as a dc-coupled hybrid (pv + battery).
What is the GVI-HR-11K4-USG’s DC input voltage range?
CEC tested it at 245–450 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
California Energy Commission — PV Module List (module electrical data for the compatibility check).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.