Cali-GrafCali-Graf
Hybrid inverterJackery

Jackery GVI-HR-7K6-USG

Hybrid inverter, dc-coupled hybrid (pv + battery). 1 model, 7.6 kW AC at 240 V.

UL 1741 SBCEC listed · Feb 21, 2025
  • Rated AC power7.6 kW
  • CEC weighted efficiency97.0%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
GVI-HR-7K6-USG: max DC 450 V · MPPT 175–450 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V6–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V6–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V7–11—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V7–11—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V7–10—
Silfab Solar SIL-440QD440 W41.1 V28 V7–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V7–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V7–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V4–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V7–11—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V7–10—
Tesla TSP-420420 W43.4 V27.7 V7–10—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 7.6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Jackery GVI-HR-xK6-USG7.6 kW–7.6 kW97.0%175–450 VYes20250
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
Qcells Q.VOLT Hx.xSX3.8 kW–7.6 kW97.5%175–500 VYes202325
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Jackery

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

GVI-HR-xxK4-USG

Questions & answers

How efficient is the Jackery GVI-HR-xK6-USG?

The California Energy Commission lists a weighted efficiency of 97.0% for Jackery GVI-HR-xK6-USG models, measured at six power levels and three DC voltages.

Is the Jackery GVI-HR-xK6-USG certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Jackery GVI-HR-xK6-USG be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the GVI-HR-7K6-USG’s DC input voltage range?

CEC tested it at 175–450 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).