Cali-GrafCali-Graf
Hybrid inverterHolu Hou Energy

Holu Hou Energy HH9600H-HI

Hybrid inverter, dc-coupled hybrid (pv + battery). 1 model, 9.6 kW AC at 240 V.

CEC listed · Mar 13, 2023
  • Rated AC power9.6 kW
  • CEC weighted efficiency97.0%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Monitoring & communication

CEC Grid Support Inverter List (Oct 7, 2026)

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HH9600H-HI: max DC 480 V · MPPT 300–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V12–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V12–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 V11–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V11–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V11–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V12–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V11–11—
Tesla TSP-420420 W43.4 V27.7 V11–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 9.6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Holu Hou Energy HHxxxxH-HI9.6 kW–9.6 kW97.0%300–480 V—20230
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

Questions & answers

How efficient is the Holu Hou Energy HHxxxxH-HI?

The California Energy Commission lists a weighted efficiency of 97.0% for Holu Hou Energy HHxxxxH-HI models, measured at six power levels and three DC voltages.

Is the Holu Hou Energy HHxxxxH-HI certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

Can the Holu Hou Energy HHxxxxH-HI be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the HH9600H-HI’s DC input voltage range?

CEC tested it at 300–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).