Hybrid inverter, dc-coupled hybrid (pv + battery). 1 model, 9.6 kW AC at 240 V.
CEC listed · Mar 13, 2023
Rated AC power9.6 kW
CEC weighted efficiency97.0%
DC input (PV side)
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC test DC voltages (min / nom / max)300 / 400 / 480 V
DC input at rated output (CEC test)9.95 kW
AC output (grid side)
CEC Grid Support Inverter List (Oct 7, 2026)
Rated AC power9.6 kW
CEC-measured continuous output9.63 kW
Grid voltage240 V
Phasesplit-phase 120/240 V
Efficiency
CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency97.0%
Night-time standby (tare)9.4 W
Power to start converting22.5 W
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.
Grid & smart-inverter certification
CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB (3rd ed.)No
UL 1741 SA (SA8–SA13)Yes — CSA Group
Volt-VAr with reactive power priority (SA13)Yes
Freq-Watt / Volt-Watt (SA14–15)Yes
Disable permit service / limit active power (SA17–18)No
CSIP (IEEE 2030.5) conformanceNo
Monitor key data & scheduling (Rule 21 Phase 3)No
Built-in meterYes
CEC listedMar 13, 2023
CEC noteThis model number can also be configured as an Isolated Inverter with Isolation Transformer HH9600H-IT which changes the overal weighted efficiency to 95.5% and night tare loss to 45.22 W.
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.
Monitoring & communication
CEC Grid Support Inverter List (Oct 7, 2026)
Built-in production meterBuilt-in meter (CEC listing)
Panel compatibility & string sizing
NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HH9600H-HI: max DC 480 V · MPPT 300–480 V (CEC test window)
Most-permitted panels in Southern California
Panel
Power
Voc cold
Vmp hot
Panels per string
Installed together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410
410 W
48.1 V
30.6 V
no fit
—
Qcells Q.PEAK DUO BLK ML-G10+ 410
410 W
48.1 V
30.6 V
no fit
—
LONGi LR5-54HABB-400M
400 W
39.3 V
25.3 V
12–12
—
JA Solar JAM54S31-405/MR
405 W
39.4 V
25.5 V
12–12
—
Hyundai Solutions HiN-T440NF(BK)
440 W
40.9 V
27 V
no fit
—
Silfab Solar SIL-440QD
440 W
41.1 V
28 V
11–11
—
Qcells Q.TRON BLK M-G2+ 430
430 W
41.3 V
28 V
11–11
—
Qcells Q.TRON BLK M-G2.H+ 430
430 W
41.3 V
28 V
11–11
—
REC Group REC460AA Pure-RX
460 W
68.8 V
47.1 V
no fit
—
Elin (Sirius PV) ELNSM54M-HC-410
410 W
39.3 V
25.3 V
12–12
—
Qcells Q.TRON BLK M-G2.C+ 430
430 W
41.3 V
28 V
11–11
—
Tesla TSP-420
420 W
43.4 V
27.7 V
11–11
—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.
Compare with similar 9.6 kW inverters
CEC Grid Support Inverter List (Oct 7, 2026) · building permits
Inverter
Power
CEC weighted eff.
DC test window
UL 1741 SB
Latest CEC
SoCal permits
Holu Hou Energy HHxxxxH-HI
9.6 kW–9.6 kW
97.0%
300–480 V
—
2023
0
SolarEdge SExxxxH-US
3 kW–11.4 kW
99.0%
360–480 V
Yes
2025
1,046
Delta Electronics Ex-TL-US
3.33 kW–9.6 kW
97.5%
200–480 V
Yes
2022
28
SolarEdge SExxxxxA-US
3.8 kW–11.4 kW
98.0%
320–500 V
No
2024
18
Growatt MIN xxxxTL-XH-US
2.63 kW–11.4 kW
98.0%
125–480 V
Yes
2021
15
Same type and grid voltage, power range covering this model; same fields from the same sources.
Questions & answers
How efficient is the Holu Hou Energy HHxxxxH-HI?
The California Energy Commission lists a weighted efficiency of 97.0% for Holu Hou Energy HHxxxxH-HI models, measured at six power levels and three DC voltages.
Is the Holu Hou Energy HHxxxxH-HI certified to UL 1741 SB?
The CEC list does not show UL 1741 SB certification for these models.
Can the Holu Hou Energy HHxxxxH-HI be used with a battery?
The CEC lists it as a dc-coupled hybrid (pv + battery).
What is the HH9600H-HI’s DC input voltage range?
CEC tested it at 300–480 V DC.
Sources
California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
California Energy Commission — PV Module List (module electrical data for the compatibility check).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.