Hybrid inverterGrowatt

Growatt WIT 40K-H-US L2

Hybrid inverter, dc-coupled hybrid (pv + battery). 4 models, 28 kW–55 kW AC at 208 V.

UL 1741 SBCEC listed · Jun 21, 2024
Model
  • Rated AC power40 kW
  • CEC weighted efficiency94.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
WIT 28K-H-US L228 kW208 V27.8 kW27.8 kW94.0%340–550 VJun 21, 2024SB
WIT 35K-H-US L235 kW208 V34.8 kW34.8 kW94.0%340–550 VJun 21, 2024SB
WIT 40K-H-US L240 kW208 V39.9 kW39.9 kW94.0%340–550 VJun 21, 2024SB
WIT 55K-H-US L255 kW208 V55 kW55 kW94.0%340–550 VJun 21, 2024SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
WIT 40K-H-US L2: max DC 550 V · MPPT 340–550 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V13–13—
Silfab Solar SIL-440QD440 W41.1 V28 V13–13—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V13–13—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V13–13—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V13–13—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 40 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Growatt WIT xxK-H-US L228 kW–55 kW94.0%340–550 VYes20240
Power Center Max Hybrid15 kW–60 kW97.5%200–850 VYes2024—
Growatt WIT xxK-HU-US L228 kW–55 kW94.0%340–550 VYes2024—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Growatt

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

MIN xxxxTL-XH-US · 15 permitsMIN xxxxTL-XH2 USSPH xxxxTL-HU-US(B)SPH 10000TL-HU-USWIT xxK-H-USWIT xxK-HU-USWIT xxK-HU-US L2SPH xxxxTL BL-US

Questions & answers

How efficient is the Growatt WIT xxK-H-US L2?

The California Energy Commission lists a weighted efficiency of 94.0% for Growatt WIT xxK-H-US L2 models, measured at six power levels and three DC voltages.

What sizes does the Growatt WIT xxK-H-US L2 come in?

The CEC list includes 4 models from 28 kW to 55 kW AC: WIT 28K-H-US L2, WIT 35K-H-US L2, WIT 40K-H-US L2, WIT 55K-H-US L2.

Is the Growatt WIT xxK-H-US L2 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Growatt WIT xxK-H-US L2 be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the WIT 40K-H-US L2’s DC input voltage range?

CEC tested it at 340–550 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).