Model
  • Rated AC power3.8 kW
  • CEC weighted efficiency97.0%
  • Max DC input600 V
  • MPPT trackers2
  • Warranty10 years

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · building permits · 18 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SBIn permits
MIN 3000TL-XH-US2.63 kW208 V2.63 kW2.63 kW96.5%125–480 VJan 21, 2021SB—
MIN 3000TL-XH-US3.1 kW240 V3.1 kW3.1 kW97.0%125–480 VJan 21, 2021SB—
MIN 3800TL-XH-US3.32 kW208 V3.32 kW3.32 kW97.0%160–480 VJan 21, 2021SB6
MIN 3800TL-XH-US3.89 kW240 V3.89 kW3.89 kW97.0%160–480 VJan 21, 2021SB6
MIN 5000TL-XH-US4.28 kW208 V4.28 kW4.28 kW97.5%210–480 VJan 21, 2021SB—
MIN 5000TL-XH-US4.94 kW240 V4.94 kW4.94 kW97.5%210–480 VJan 21, 2021SB—
MIN 6000TL-XH-US5.14 kW208 V5.14 kW5.14 kW97.0%170–480 VJan 21, 2021SB3
MIN 6000TL-XH-US5.92 kW240 V5.92 kW5.92 kW97.0%170–480 VJan 21, 2021SB3
MIN 7600TL-XH-US6.58 kW208 V6.58 kW6.58 kW97.0%212–480 VJan 21, 2021SB6
MIN 7600TL-XH-US7.52 kW240 V7.52 kW7.52 kW97.5%212–480 VJan 21, 2021SB6
MIN 8200TL-XH-US8.2 kW208 V7.17 kW7.17 kW97.5%250–480 VMar 22, 2021SB—
MIN 8200TL-XH-US8.2 kW240 V8.25 kW8.25 kW97.5%250–480 VMar 22, 2021SB—
MIN 9000TL-XH-US9 kW208 V7.87 kW7.87 kW97.5%250–480 VMar 22, 2021SB—
MIN 9000TL-XH-US9 kW240 V9.06 kW9.06 kW97.5%250–480 VMar 22, 2021SB—
MIN 10000TL-XH-US10 kW208 V8.76 kW8.76 kW97.5%250–480 VMar 22, 2021SB—
MIN 10000TL-XH-US10 kW240 V10.1 kW10.1 kW97.5%250–480 VMar 22, 2021SB—
MIN 11400TL-XH-US11.4 kW208 V10 kW10 kW97.5%250–480 VMar 22, 2021SB—
MIN 11400TL-XH-US11.4 kW240 V11.5 kW11.5 kW98.0%250–480 VMar 22, 2021SB—
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

Growatt datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

Growatt datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Growatt datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · Growatt datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Backup power

Growatt datasheet

Safety & protection

Growatt datasheet

Monitoring & communication

Growatt datasheet

Size, weight & environment

Growatt datasheet

Warranty

Growatt datasheet

Panel compatibility & string sizing

Growatt datasheet · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
MIN 3800TL-XH-US: max DC 600 V · MPPT 130–500 V (datasheet)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V6–157
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V5–122
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V5–12—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V6–15—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V5–14—
Silfab Solar SIL-440QD440 W41.1 V28 V5–14—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V5–14—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V5–14—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V3–8—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V6–15—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V5–14—
Tesla TSP-420420 W43.4 V27.7 V5–13—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

What it's installed with

building permits

Panels

JA Solar JAM54S31-xxx/MR
7
Qcells Q.PEAK DUO
2

Optimizers

Tigo TS4
4
Permits naming both; 12 of 15 permits list other equipment.

Installed in Southern California

building permits
15
Permits name it
Nov 2022 – Apr 2026
2
Jurisdictions so far
LA County (unincorp.) (13), Palmdale (2)
6.3 kW
Typical system
median of 15 permits

Permits over time

1Q4 ’2227Q2 ’2301Q4 ’2320Q2 ’2400Q4 ’2400Q2 ’2510Q4 ’2501Q2 ’26permits per quarter

Model named in permit

MIN 7600TL-XH-US
6
MIN 3800TL-XH-US
6
MIN 6000TL-XH-US
3

Top ZIP codes

  • ZIP 910013
  • ZIP 935502
  • ZIP 906012
  • ZIP 906062
  • Other ZIP codes6
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 3.8 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW97.0%160–480 VYes202130
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
Qcells Q.VOLT Hx.xSX3.8 kW–7.6 kW97.5%175–500 VYes202325
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Same type and grid voltage, power range covering this model; same fields from the same sources.

Approved in other markets

Clean Energy Council (Australia)
ModelApprovedExpiresStandards
MIN 10000TL-X2Sep 2, 2024Sep 2, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
MIN 3000TL-XH2Jul 10, 2024Jul 10, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
MIN 5000TL-XH2Jul 10, 2024Jul 10, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
MIN 6000TL-XH2Jul 10, 2024Jul 10, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
MIN 9000TL-X2Sep 2, 2024Sep 2, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020

About Growatt

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

MIN xxxxTL-XH2 USSPH xxxxTL-HU-US(B)SPH 10000TL-HU-USWIT xxK-H-USWIT xxK-H-US L2WIT xxK-HU-USWIT xxK-HU-US L2SPH xxxxTL BL-US

Documents

manufacturer documents

Questions & answers

How efficient is the Growatt MIN xxxxTL-XH-US?

The California Energy Commission lists a weighted efficiency of 96.5–98.0% for Growatt MIN xxxxTL-XH-US models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 98.0%.

What sizes does the Growatt MIN xxxxTL-XH-US come in?

The CEC list includes 18 models from 2.63 kW to 11.4 kW AC: MIN 3000TL-XH-US, MIN 3000TL-XH-US, MIN 3800TL-XH-US, MIN 3800TL-XH-US, MIN 5000TL-XH-US, MIN 5000TL-XH-US, MIN 6000TL-XH-US, MIN 6000TL-XH-US….

Is the Growatt MIN xxxxTL-XH-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Growatt MIN xxxxTL-XH-US be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the MIN 3800TL-XH-US’s DC input voltage range?

Max DC input voltage is 600 V per the datasheet. CEC tested it at 160–480 V DC.

What warranty does it have?

10 years standard (manufacturer datasheet).

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Growatt — manufacturer datasheet “MIN3000~7600TL-XH-US · Batter y Ready for DC Coupled and AC coupled system”.
  3. Growatt — datasheet MIN 3000-7600TL-XH-US Canada Version Datasheet EN.
  4. Growatt — document library on the manufacturer’s website (links above).
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  8. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Nov 2022 – Apr 2026); City of Palmdale (Oct 2023 – Mar 2024). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).