Cali-GrafCali-Graf
String inverterGoodWe

GoodWe GW28KLV-SMT-US

String inverter. 4 models, 22 kW–28 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Nov 12, 2024
Model
  • Rated AC power28 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
GW22KLV-SMT-US22 kW208 V22.2 kW22.2 kW97.0%350–750 VNov 12, 2024SB
GW22KLV-SMT-US22 kW240 V25 kW25 kW97.0%350–750 VNov 12, 2024SB
GW28KLV-SMT-US28 kW208 V28.2 kW28.2 kW97.0%350–750 VNov 12, 2024SB
GW28KLV-SMT-US28 kW240 V32.1 kW32.1 kW97.0%350–750 VNov 12, 2024SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
GW28KLV-SMT-US: max DC 750 V · MPPT 350–750 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V12–15—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V12–15—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V14–19—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V14–19—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V13–18—
Silfab Solar SIL-440QD440 W41.1 V28 V13–18—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V13–18—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V13–18—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V8–10—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V14–19—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V13–18—
Tesla TSP-420420 W43.4 V27.7 V13–17—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 28 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
GoodWe GWxxKLV-SMT-US22 kW–28 kW97.0%350–750 VYes20240
Solis (Ginlong Technologies) S6-GC30K-LV-US30 kW–30 kW97.0%340–680 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About GoodWe

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

GEPx.x-1-US30GW11K4-MS-US30GWxxK-SMT-USGWxxxx-MS-US30GWxxxxA-MS

Questions & answers

How efficient is the GoodWe GWxxKLV-SMT-US?

The California Energy Commission lists a weighted efficiency of 97.0% for GoodWe GWxxKLV-SMT-US models, measured at six power levels and three DC voltages.

What sizes does the GoodWe GWxxKLV-SMT-US come in?

The CEC list includes 4 models from 22 kW to 28 kW AC: GW22KLV-SMT-US, GW22KLV-SMT-US, GW28KLV-SMT-US, GW28KLV-SMT-US.

Is the GoodWe GWxxKLV-SMT-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the GW28KLV-SMT-US’s DC input voltage range?

CEC tested it at 350–750 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).