Cali-GrafCali-Graf
String inverterGoodWe

GoodWe GW60K-SMT-US

String inverter. 2 models, 50 kW–60 kW AC at 480 V.

UL 1741 SBCEC listed · Dec 12, 2022
Model
  • Rated AC power60 kW
  • CEC weighted efficiency98.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
GW50K-SMT-US50 kW480 V51.3 kW51.3 kW98.0%550–850 VDec 12, 2022SB
GW60K-SMT-US60 kW480 V61.5 kW61.5 kW98.0%550–850 VDec 12, 2022SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
GW60K-SMT-US: max DC 850 V · MPPT 550–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 V20–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V20–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V20–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V20–20—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 60 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
GoodWe GWxxK-SMT-US50 kW–60 kW98.0%550–850 VYes20220
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%400–850 VYes20233
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About GoodWe

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

GWxxKLV-SMT-USGEPx.x-1-US30GW11K4-MS-US30GWxxxx-MS-US30GWxxxxA-MS

Questions & answers

How efficient is the GoodWe GWxxK-SMT-US?

The California Energy Commission lists a weighted efficiency of 98.0% for GoodWe GWxxK-SMT-US models, measured at six power levels and three DC voltages.

What sizes does the GoodWe GWxxK-SMT-US come in?

The CEC list includes 2 models from 50 kW to 60 kW AC: GW50K-SMT-US, GW60K-SMT-US.

Is the GoodWe GWxxK-SMT-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the GW60K-SMT-US’s DC input voltage range?

CEC tested it at 550–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).