Cali-GrafCali-Graf
String inverterGoodWe

GoodWe GW11K4-MS-US30

String inverter. 2 models, 9.88 kW–11.4 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Dec 21, 2022
Model
  • Rated AC power11.4 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
GW11K4-MS-US309.88 kW208 V9.88 kW9.88 kW96.5%217–500 VDec 21, 2022SB
GW11K4-MS-US3011.4 kW240 V11.4 kW11.4 kW97.0%250–500 VDec 21, 2022SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
GW11K4-MS-US30: max DC 500 V · MPPT 250–500 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V9–10—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V9–10—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–12—
Silfab Solar SIL-440QD440 W41.1 V28 V9–12—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–12—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–12—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–7—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–12—
Tesla TSP-420420 W43.4 V27.7 V10–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 11.4 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
GoodWe GW11K4-MS-US309.88 kW–11.4 kW97.0%250–500 VYes20220
GoodWe GEPx.x-1-US304.33 kW–11.4 kW97.0%143–500 VYes2022—
GoodWe GWxxxx-MS-US304.33 kW–9.6 kW97.0%143–500 VYes2022—
GoodWe GWxxxxA-MS5 kW–9.6 kW97.5%210–480 VYes2021—
Fronius Fronius Symo Advanced xx.x-3 208-240 Lite10 kW–12 kW96.5%300–480 VNo2020—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About GoodWe

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

GWxxKLV-SMT-USGEPx.x-1-US30GWxxK-SMT-USGWxxxx-MS-US30GWxxxxA-MS

Questions & answers

How efficient is the GoodWe GW11K4-MS-US30?

The California Energy Commission lists a weighted efficiency of 96.5–97.0% for GoodWe GW11K4-MS-US30 models, measured at six power levels and three DC voltages.

What sizes does the GoodWe GW11K4-MS-US30 come in?

The CEC list includes 2 models from 9.88 kW to 11.4 kW AC: GW11K4-MS-US30, GW11K4-MS-US30.

Is the GoodWe GW11K4-MS-US30 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the GW11K4-MS-US30’s DC input voltage range?

CEC tested it at 250–500 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).