Hybrid inverterFronius

Fronius Primo GEN24 6.0 208-240

Hybrid inverter, dc-coupled hybrid (pv + battery). 10 models, 3.8 kW–10 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Nov 12, 2021
Model
  • Rated AC power6 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 10 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
Primo GEN24 3.8 208-2403.8 kW208 V3.81 kW3.81 kW96.5%200–480 VNov 12, 2021SB
Primo GEN24 3.8 208-2403.8 kW240 V3.8 kW3.8 kW96.5%200–480 VNov 12, 2021SB
Primo GEN24 5.0 208-2405 kW208 V5.01 kW5.01 kW97.0%230–480 VNov 12, 2021SB
Primo GEN24 5.0 208-2405 kW240 V5.01 kW5.01 kW97.0%230–480 VNov 12, 2021SB
Primo GEN24 6.0 208-2406 kW208 V5.74 kW5.74 kW97.0%230–480 VNov 12, 2021SB
Primo GEN24 6.0 208-2406 kW240 V6 kW6 kW97.0%230–480 VNov 12, 2021SB
Primo GEN24 7.7 208-2407.7 kW208 V7.69 kW7.69 kW96.5%260–480 VSep 3, 2024SB
Primo GEN24 7.7 208-2407.7 kW240 V7.69 kW7.69 kW97.0%260–480 VSep 3, 2024SB
Primo GEN24 10.0 208-24010 kW208 V9.45 kW9.45 kW96.5%260–480 VSep 3, 2024SB
Primo GEN24 10.0 208-24010 kW240 V10 kW10 kW97.0%260–480 VSep 3, 2024SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

CEC Grid Support Inverter List (Oct 7, 2026)

Monitoring & communication

CEC Grid Support Inverter List (Oct 7, 2026)

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
Primo GEN24 6.0 208-240: max DC 480 V · MPPT 230–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V8–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V8–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V9–11—
Silfab Solar SIL-440QD440 W41.1 V28 V9–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–11—
Tesla TSP-420420 W43.4 V27.7 V9–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Fronius Primo GEN24 x.x 208-2403.8 kW–10 kW97.0%230–480 VYes20240
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
Qcells Q.VOLT Hx.xSX3.8 kW–7.6 kW97.5%175–500 VYes202325
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Same type and grid voltage, power range covering this model; same fields from the same sources.

Approved in other markets

Clean Energy Council (Australia)
ModelApprovedExpiresStandards
Primo GEN24 10.0Aug 14, 2026Aug 14, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 10.0 PlusAug 14, 2026Aug 14, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 3.0Jan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
Primo GEN24 3.0 PlusJan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
Primo GEN24 3.0 Plus SCJul 30, 2026Jul 30, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 3.0 SCJul 30, 2026Jul 30, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 3.6Jan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
Primo GEN24 3.6 PlusJan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
Primo GEN24 3.6 Plus SCJul 30, 2026Jul 30, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 3.6 SCJul 30, 2026Jul 30, 2029IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024
Primo GEN24 4.0Jan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020
Primo GEN24 4.0 PlusJan 7, 2025Jan 3, 2027IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020

About Fronius

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Primo GEN24 x.x 208-240 Plus

Questions & answers

How efficient is the Fronius Primo GEN24 x.x 208-240?

The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Fronius Primo GEN24 x.x 208-240 models, measured at six power levels and three DC voltages.

What sizes does the Fronius Primo GEN24 x.x 208-240 come in?

The CEC list includes 10 models from 3.8 kW to 10 kW AC: Primo GEN24 3.8 208-240, Primo GEN24 3.8 208-240, Primo GEN24 5.0 208-240, Primo GEN24 5.0 208-240, Primo GEN24 6.0 208-240, Primo GEN24 6.0 208-240, Primo GEN24 7.7 208-240, Primo GEN24 7.7 208-240….

Is the Fronius Primo GEN24 x.x 208-240 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Fronius Primo GEN24 x.x 208-240 be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the Primo GEN24 6.0 208-240’s DC input voltage range?

CEC tested it at 230–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. Clean Energy Council (Australia) — approved inverter list (as of Oct 8, 2026).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).