Hybrid inverter, dc-coupled hybrid (pv + battery). 10 models, 3.8 kW–10 kW AC at 208 V / 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| Primo GEN24 3.8 208-240 Plus | 3.8 kW | 208 V | 3.81 kW | 3.81 kW | 96.5% | 200–480 V | Nov 12, 2021 | SB |
| Primo GEN24 3.8 208-240 Plus | 3.8 kW | 240 V | 3.8 kW | 3.8 kW | 96.5% | 200–480 V | Nov 12, 2021 | SB |
| Primo GEN24 5.0 208-240 Plus | 5 kW | 208 V | 5.01 kW | 5.01 kW | 97.0% | 230–480 V | Nov 12, 2021 | SB |
| Primo GEN24 5.0 208-240 Plus | 5 kW | 240 V | 5.01 kW | 5.01 kW | 97.0% | 230–480 V | Nov 12, 2021 | SB |
| Primo GEN24 6.0 208-240 Plus | 6 kW | 208 V | 5.74 kW | 5.74 kW | 97.0% | 230–480 V | Nov 12, 2021 | SB |
| Primo GEN24 6.0 208-240 Plus | 6 kW | 240 V | 6 kW | 6 kW | 97.0% | 230–480 V | Nov 12, 2021 | SB |
| Primo GEN24 7.7 208-240 Plus | 7.7 kW | 208 V | 7.69 kW | 7.69 kW | 96.5% | 260–480 V | Sep 3, 2024 | SB |
| Primo GEN24 7.7 208-240 Plus | 7.7 kW | 240 V | 7.69 kW | 7.69 kW | 97.0% | 260–480 V | Sep 3, 2024 | SB |
| Primo GEN24 10.0 208-240 Plus | 10 kW | 208 V | 9.45 kW | 9.45 kW | 96.5% | 260–480 V | Sep 3, 2024 | SB |
| Primo GEN24 10.0 208-240 Plus | 10 kW | 240 V | 10 kW | 10 kW | 97.0% | 260–480 V | Sep 3, 2024 | SB |
| Panel | Power | Voc cold | Vmp hot | Panels per string | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 V | 30.6 V | 8–9 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 V | 30.6 V | 8–9 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 V | 25.3 V | 10–12 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 V | 25.5 V | 10–12 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 V | 27 V | 9–11 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 V | 28 V | 9–11 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 V | 28 V | 9–11 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 V | 28 V | 9–11 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 V | 47.1 V | 5–6 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 V | 25.3 V | 10–12 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 V | 28 V | 9–11 | — |
| Tesla TSP-420 | 420 W | 43.4 V | 27.7 V | 9–11 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Fronius Primo GEN24 x.x 208-240 Plus | 3.8 kW–10 kW | 97.0% | 230–480 V | Yes | 2024 | 0 |
| SolarEdge SExxxxH-US | 3 kW–11.4 kW | 99.0% | 360–480 V | Yes | 2025 | 1,046 |
| Delta Electronics Ex-TL-US | 3.33 kW–9.6 kW | 97.5% | 200–480 V | Yes | 2022 | 28 |
| Qcells Q.VOLT Hx.xSX | 3.8 kW–7.6 kW | 97.5% | 175–500 V | Yes | 2023 | 25 |
| SolarEdge SExxxxxA-US | 3.8 kW–11.4 kW | 98.0% | 320–500 V | No | 2024 | 18 |
| Model | Approved | Expires | Standards |
|---|---|---|---|
| Primo GEN24 10.0 | Aug 14, 2026 | Aug 14, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 10.0 Plus | Aug 14, 2026 | Aug 14, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 3.0 | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| Primo GEN24 3.0 Plus | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| Primo GEN24 3.0 Plus SC | Jul 30, 2026 | Jul 30, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 3.0 SC | Jul 30, 2026 | Jul 30, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 3.6 | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| Primo GEN24 3.6 Plus | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| Primo GEN24 3.6 Plus SC | Jul 30, 2026 | Jul 30, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 3.6 SC | Jul 30, 2026 | Jul 30, 2029 | IEC 62109-1;IEC 62109-2;AS/NZS 4777.2:2020 Amd 2:2024 |
| Primo GEN24 4.0 | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
| Primo GEN24 4.0 Plus | Jan 7, 2025 | Jan 3, 2027 | IEC 62109.1;IEC 62109.2;AS/NZS 4777.2:2020 |
The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Fronius Primo GEN24 x.x 208-240 Plus models, measured at six power levels and three DC voltages.
The CEC list includes 10 models from 3.8 kW to 10 kW AC: Primo GEN24 3.8 208-240 Plus, Primo GEN24 3.8 208-240 Plus, Primo GEN24 5.0 208-240 Plus, Primo GEN24 5.0 208-240 Plus, Primo GEN24 6.0 208-240 Plus, Primo GEN24 6.0 208-240 Plus, Primo GEN24 7.7 208-240 Plus, Primo GEN24 7.7 208-240 Plus….
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
The CEC lists it as a dc-coupled hybrid (pv + battery).
CEC tested it at 230–480 V DC.