Cali-GrafCali-Graf
Hybrid inverterFOXESS

FOXESS H3-150-Plus-US-H

Hybrid inverter, dc-coupled hybrid (pv + battery). 1 model, 150 kW AC at 480 V.

UL 1741 SBCEC listed · Sep 1, 2026
  • Rated AC power150 kW
  • CEC weighted efficiency97.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026)

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026)
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

CEC Grid Support Inverter List (Oct 7, 2026) · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
H3-150-Plus-US-H: max DC 850 V · MPPT 540–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V20–20—
Silfab Solar SIL-440QD440 W41.1 V28 V20–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V20–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V20–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V20–20—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 150 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
FOXESS H3-xxx-Plus-US-H150 kW–150 kW97.5%540–850 VYes20260
Solis (Ginlong Technologies) S6-EH3PxxxK10-NV-YD-H-US100 kW–150 kW97.5%550–900 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About FOXESS

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

H1-x.x-US · 1 permitsH3-xx-Plus-US-LAIO-H1-x.x-US

Questions & answers

How efficient is the FOXESS H3-xxx-Plus-US-H?

The California Energy Commission lists a weighted efficiency of 97.5% for FOXESS H3-xxx-Plus-US-H models, measured at six power levels and three DC voltages.

Is the FOXESS H3-xxx-Plus-US-H certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the FOXESS H3-xxx-Plus-US-H be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the H3-150-Plus-US-H’s DC input voltage range?

CEC tested it at 540–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  3. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  4. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).