Model
  • Rated AC power9.6 kW
  • CEC weighted efficiency97.0%
  • Max DC input600 V
  • Warranty10 years

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 5 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
H1-3.8-US3.8 kW240 V3.71 kW3.71 kW96.0%204–480 VFeb 13, 2023SB
H1-5.7-US5.7 kW240 V5.75 kW5.75 kW97.0%204–480 VFeb 13, 2023SB
H1-7.6-US7.6 kW240 V7.72 kW7.72 kW97.0%271–480 VFeb 13, 2023SB
H1-9.6-US9.6 kW240 V9.61 kW9.61 kW97.0%257–480 VFeb 13, 2023SB
H1-11.4-US11.4 kW240 V11.5 kW11.5 kW97.5%305–480 VOct 21, 2022SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

FOXESS datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · Cali-Graf calculation

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026) · FOXESS datasheet

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · FOXESS datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026) · FOXESS datasheet
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Backup power

FOXESS datasheet

Safety & protection

FOXESS datasheet

Monitoring & communication

FOXESS datasheet

Size, weight & environment

FOXESS datasheet

Warranty

FOXESS datasheet

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
H1-9.6-US: max DC 480 V · MPPT 257–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V9–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V9–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V11–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V11–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–11—
Silfab Solar SIL-440QD440 W41.1 V28 V10–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V10–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V10–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V11–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V10–11—
Tesla TSP-420420 W43.4 V27.7 V10–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Installed in Southern California

building permits
1
Permits name it
Jan 2026
1
Jurisdictions so far
LA County (unincorp.) (1)

Model named in permit

H1-9.6-US
1
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 9.6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
FOXESS H1-x.x-US3.8 kW–11.4 kW97.0%257–480 VYes20231
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

About FOXESS

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

H3-xx-Plus-US-LH3-xxx-Plus-US-HAIO-H1-x.x-US

Questions & answers

How efficient is the FOXESS H1-x.x-US?

The California Energy Commission lists a weighted efficiency of 96.0–97.5% for FOXESS H1-x.x-US models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 97.6%.

What sizes does the FOXESS H1-x.x-US come in?

The CEC list includes 5 models from 3.8 kW to 11.4 kW AC: H1-3.8-US, H1-5.7-US, H1-7.6-US, H1-9.6-US, H1-11.4-US.

Is the FOXESS H1-x.x-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the FOXESS H1-x.x-US be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the H1-9.6-US’s DC input voltage range?

Max DC input voltage is 600 V per the datasheet. CEC tested it at 257–480 V DC.

What warranty does it have?

10 years standard (manufacturer datasheet).

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. FOXESS — manufacturer datasheet “Split-Phase Hybrid H1&AC1-3.8-US / 5.7 / 7.6 / 9.6 / 11.4”.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jan 2026). Equipment matched from permit descriptions by model number.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).