Hybrid inverterFortress Power

Fortress Power FP-Envy Duo 21

Hybrid inverter, dc-coupled hybrid (pv + battery). 2 models, 13.8 kW–16 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Nov 21, 2025
Model
  • Rated AC power16 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
FP-Envy Duo 2113.8 kW208 V13.9 kW13.9 kW96.5%250–440 VNov 21, 2025SB
FP-Envy Duo 2116 kW240 V16.2 kW16.2 kW97.0%250–440 VNov 21, 2025SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
FP-Envy Duo 21: max DC 440 V · MPPT 250–440 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V9–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V9–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–11—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–11—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–10—
Silfab Solar SIL-440QD440 W41.1 V28 V9–10—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–10—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–10—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–11—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–10—
Tesla TSP-420420 W43.4 V27.7 V10–10—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 16 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Fortress Power FP-Envy Duo 2113.8 kW–16 kW97.0%250–440 VYes20250
Shenzhen Lux Power Technology LXP-LB-US xK8 kW–16 kW97.0%210–480 VYes20251
Suzhou Ample ESS AP-LxK-SPUS7.98 kW–15 kW96.5%108–480 VYes2026—
SRNE Solar HEBP48150U320-H15 kW–15 kW96.5%135–500 VYes2026—
SRNE Solar HEBP48160U340-H16 kW–16 kW96.5%150–500 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Fortress Power

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

EdgeOn Duo 12EdgeOn Duo 12 LiteEdgeOn Duo 15EdgeOn Duo 15 LiteEdgeOn Duo 15 ProEdgeOn Duo 7.5EdgeOn Duo 9FP-Nano-30k-LFP-Nano-xxk-NFP-ENVY-xxK

Questions & answers

How efficient is the Fortress Power FP-Envy Duo 21?

The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Fortress Power FP-Envy Duo 21 models, measured at six power levels and three DC voltages.

What sizes does the Fortress Power FP-Envy Duo 21 come in?

The CEC list includes 2 models from 13.8 kW to 16 kW AC: FP-Envy Duo 21, FP-Envy Duo 21.

Is the Fortress Power FP-Envy Duo 21 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Fortress Power FP-Envy Duo 21 be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the FP-Envy Duo 21’s DC input voltage range?

CEC tested it at 250–440 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).