Cali-GrafCali-Graf
Hybrid inverterEternalplanet Energy

Eternalplanet Energy HNA2-S11G5

Hybrid inverter, dc-coupled hybrid (pv + battery). 7 models, 5 kW–11.5 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Jul 21, 2026
Model
  • Rated AC power9.6 kW
  • CEC weighted efficiency96.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · 7 models
ModelNominal ACGrid voltageCEC continuousCEC weighted eff.DC test windowCEC listedUL 1741 SB
HNA2-S11G5 +2 SKU5 kW208 V5.03 kW95.5%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU5.8 kW240 V5.81 kW96.0%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU6.6 kW208 V6.68 kW96.0%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU7.6 kW240 V7.6 kW96.5%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU9.6 kW240 V9.63 kW96.0%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU9.9 kW208 V9.9 kW95.5%250–480 VJul 21, 2026SB
HNA2-S11G5 +2 SKU11.5 kW240 V11.3 kW96.0%250–480 VJul 21, 2026SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026)
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

CEC Grid Support Inverter List (Oct 7, 2026) · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HNA2-S11G5: max DC 480 V · MPPT 250–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V9–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V9–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V10–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V10–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V10–11—
Silfab Solar SIL-440QD440 W41.1 V28 V9–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V9–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V9–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V10–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V9–11—
Tesla TSP-420420 W43.4 V27.7 V10–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 9.6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Eternalplanet Energy HNA2-SxxGxx5 kW–11.5 kW96.0%250–480 VYes20260
SolarEdge SExxxxH-US3 kW–11.4 kW99.0%360–480 VYes20251,046
Delta Electronics Ex-TL-US3.33 kW–9.6 kW97.5%200–480 VYes202228
SolarEdge SExxxxxA-US3.8 kW–11.4 kW98.0%320–500 VNo202418
Growatt MIN xxxxTL-XH-US2.63 kW–11.4 kW98.0%125–480 VYes202115
Same type and grid voltage, power range covering this model; same fields from the same sources.

Questions & answers

How efficient is the Eternalplanet Energy HNA2-SxxGxx?

The California Energy Commission lists a weighted efficiency of 95.5–96.5% for Eternalplanet Energy HNA2-SxxGxx models, measured at six power levels and three DC voltages.

What sizes does the Eternalplanet Energy HNA2-SxxGxx come in?

The CEC list includes 7 models from 5 kW to 11.5 kW AC: HNA2-S11G5, HNA2-S11G5, HNA2-S11G5, HNA2-S11G5, HNA2-S11G5, HNA2-S11G5, HNA2-S11G5.

Is the Eternalplanet Energy HNA2-SxxGxx certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the Eternalplanet Energy HNA2-SxxGxx be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the HNA2-S11G5’s DC input voltage range?

CEC tested it at 250–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  3. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  4. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).