Cali-GrafCali-Graf
Hybrid inverterEcoFlow

EcoFlow EF-PCS-24

Hybrid inverter, dc-coupled hybrid (pv + battery). 4 models, 11.5 kW–24 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · Aug 11, 2025
Model
  • Rated AC power24 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
EF-PCS-2411.5 kW208 V11.4 kW11.4 kW96.0%120–480 VAug 11, 2025SB
EF-PCS-2411.5 kW240 V11.4 kW11.4 kW96.0%120–480 VAug 11, 2025SB
EF-PCS-2424 kW208 V24.3 kW24.3 kW96.5%320–480 VAug 11, 2025SB
EF-PCS-2424 kW240 V24 kW24 kW97.0%320–480 VAug 11, 2025SB
Some models are also on the CEC Battery Inverter list — one product, two listings.

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
EF-PCS-24: max DC 480 V · MPPT 320–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 Vno fit—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 Vno fit—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 Vno fit—
REC Group REC460AA Pure-RX460 W68.8 V47.1 Vno fit—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 Vno fit—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 24 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
EcoFlow EF-PCS-2411.5 kW–24 kW97.0%320–480 VYes20250
Fortress Power FP-Nano-30k-L25.9 kW–29.8 kW97.0%500–850 VYes2026—
Shenzhen Lux Power Technology GEN-HB-US 25K21.6 kW–25 kW96.5%190–480 VYes2026—
Sinexcel Isuna UxxK-PH10 kW–20 kW97.0%140–500 VYes2026—
Solis (Ginlong Technologies) S6-EH3P30K03-LV-YD-H-US(21A)25.9 kW–29.8 kW97.0%500–850 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Questions & answers

How efficient is the EcoFlow EF-PCS-24?

The California Energy Commission lists a weighted efficiency of 96.0–97.0% for EcoFlow EF-PCS-24 models, measured at six power levels and three DC voltages.

What sizes does the EcoFlow EF-PCS-24 come in?

The CEC list includes 4 models from 11.5 kW to 24 kW AC: EF-PCS-24, EF-PCS-24, EF-PCS-24, EF-PCS-24.

Is the EcoFlow EF-PCS-24 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

Can the EcoFlow EF-PCS-24 be used with a battery?

The CEC lists it as a dc-coupled hybrid (pv + battery).

What is the EF-PCS-24’s DC input voltage range?

CEC tested it at 320–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).