Cali-GrafCali-Graf
String inverterDelta Electronics

Delta Electronics M80U_280

String inverter. 3 models, 60 kW–100 kW AC at 480 V.

CEC listed · May 11, 2022
Model
  • Rated AC power83 kW
  • CEC weighted efficiency98.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 3 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
M60U_28060 kW480 V60 kW60 kW98.5%550–840 VMay 11, 2022—
M80U_28083 kW480 V80 kW80 kW98.5%550–840 VMay 11, 2022—
M100U_280100 kW480 V100 kW100 kW98.5%550–840 VMay 11, 2022—

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
M80U_280: max DC 840 V · MPPT 550–840 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 Vno fit—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 Vno fit—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 Vno fit—
Silfab Solar SIL-440QD440 W41.1 V28 V20–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V20–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V20–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V12–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 Vno fit—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V20–20—
Tesla TSP-420420 W43.4 V27.7 Vno fit—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 83 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Delta Electronics MxxU_28060 kW–100 kW98.5%550–840 V—20220
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
Solis (Ginlong Technologies) Solis-xxK-5G-US75 kW–100 kW98.5%550–850 VNo20203
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Yaskawa Solectria Solar PVI xxTL-48036 kW–100 kW98.5%340–850 V3 of 42025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Delta Electronics

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

DPxxxU-US-XXMxxU_260M10-4-TL-US

Questions & answers

How efficient is the Delta Electronics MxxU_280?

The California Energy Commission lists a weighted efficiency of 98.5% for Delta Electronics MxxU_280 models, measured at six power levels and three DC voltages.

What sizes does the Delta Electronics MxxU_280 come in?

The CEC list includes 3 models from 60 kW to 100 kW AC: M60U_280, M80U_280, M100U_280.

Is the Delta Electronics MxxU_280 certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

What is the M80U_280’s DC input voltage range?

CEC tested it at 550–840 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).