Model
  • Rated AC power9.6 kW
  • CEC weighted efficiency97.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
M10-4-TL-US8.32 kW208 V8.38 kW8.38 kW97.5%280–480 VAug 11, 2020SB
M10-4-TL-US9.6 kW240 V9.67 kW9.67 kW97.5%280–480 VAug 11, 2020SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Monitoring & communication

CEC Grid Support Inverter List (Oct 7, 2026)

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
M10-4-TL-US: max DC 480 V · MPPT 280–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 Vno fit—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 Vno fit—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V12–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V11–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V11–11—
Silfab Solar SIL-440QD440 W41.1 V28 V11–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V11–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V11–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V6–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V12–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V11–11—
Tesla TSP-420420 W43.4 V27.7 V11–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 9.6 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Delta Electronics M10-4-TL-US8.32 kW–9.6 kW97.5%280–480 VYes20200
Tesla 1538000-xx-y6.66 kW–7.68 kW98.0%270–480 VYes202174
GoodWe GEPx.x-1-US304.33 kW–11.4 kW97.0%143–500 VYes2022—
GoodWe GW11K4-MS-US309.88 kW–11.4 kW97.0%217–500 VYes2022—
GoodWe GWxxxx-MS-US304.33 kW–9.6 kW97.0%143–500 VYes2022—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Delta Electronics

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

DPxxxU-US-XXMxxU_260MxxU_280

Questions & answers

How efficient is the Delta Electronics M10-4-TL-US?

The California Energy Commission lists a weighted efficiency of 97.5% for Delta Electronics M10-4-TL-US models, measured at six power levels and three DC voltages.

What sizes does the Delta Electronics M10-4-TL-US come in?

The CEC list includes 2 models from 8.32 kW to 9.6 kW AC: M10-4-TL-US, M10-4-TL-US.

Is the Delta Electronics M10-4-TL-US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the M10-4-TL-US’s DC input voltage range?

CEC tested it at 280–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).